7. Complete the final test of the installation. Be
sure the primary pump is still disconnected from
power. Unplug the controller from the 115V
outlet. Run water into the sump basin until the
backup pump turns on. Check all connections
for leaks.
AC
POWER
FLOAT
STATUS
BATTERY
DC
PUMP
SILENCE
TEST
24/7 BASEMENT
PROTECTION
USB
RESET
FLOAT
DC
PUMP
FUSE
30 AMP
by
1-800-584-8089
BasementSentry.com
DC POWER
+ 15V DC 1.6A
Unplug
controller to test
7
8. Push the ‘Silence’ button when the pump is
running to turn off the alarm. The pump will
continue to run for an additional ten seconds
after the float has been lowered or until the
controller senses water is being pumped.
9. Press and hold the ‘Silence’ button for three
seconds to reset the system and clear all faults