Please review the following troubleshooting questions before returning a pump as defective.
If you have any questions, please call Customer Service at (800) 584-8089.
MODEL
LIQUID PUMP
LR90197
US
REV
DATE CODE:/CÓDIGO DE FECHA
Made in USA • Hecho en EE.UU.
Kendallville, IN 46755 • USA
QUICK TROUBLE-SHOOTING CHECKLIST
20
20
20
20
RESETRESET
TESTTEST
IL1381
C
US
LR90197
UL Std. No. 778
ENCLOSURE 3
starwatersystems.com
Pump:
JHU10
Rev:
B
Motor:
98U1071
HP:
1
PH
1
Hz
60
Volts
115/230
S.F.
1.2
Amps
14/7
S.F. Amps:
14/7
RPM
3450
Type
C
Duty:
Cont.
Temp
65C
KVA Code
G
Frame
56L
Ins Class
B
Factory prewired for 230V
Thermally protected automatically
Check voltage of power source
Use copper conductors only
ELECTRICAL HAZARD
Improper installation may result in fi re, explosion, electrical short or injury. Replace all covers
before operating. Ground motor in accordance with local and national electrical codes.
Disconnect power source before touching internal parts. Motors equipped with automatic
protection may restart without warning.
See instruction manual for proper installation procedure.
Se reporter au manuel d’instructions pour suivre la procédure adéquate d’installation.
Consulte el instructive para conocer el procedimiento de instalación correcto.
L1
L2
A
B
L1
L2
A
B
IL0180
YELLOW
115 VOLT
SINGLE PHASE
LINE
230 VOLT
SINGLE PHASE
LINE
WHITE
GRAY
RED
TAN
YELLOW
WHITE
GRAY
RED
TAN
DATE CODE:
0418*
Made in USA
Pressure Switch
1. Check date code to make sure pump is within
warranty period. Date code is the month and
the year.
(Example: 0318 is March of 2018. Date Code is
found on the top of the pump.)
2. Make certain that the power source matches the
pump requirements. This pump has a dual voltage
motor and can run on 115 V or 230 V. This pump is
pre-wired at the factory to run on 230 V.
3. If pump does not run, check the GFI or breaker
panel switch to make sure it is in full operation.
4. If the pump runs all the time, make sure the
pump has been primed correctly. If pump is not
holding the prime, inspect check valve, foot
valve, and piping, then reprime.
5. If the pump runs but won’t shut off, check
pressure switch.