FOR
DEEP
WELL
APPLICA
TIONS
2
5 -
7
0
FT
.
12
© 2020. All rights reserved.
Wire from
motor
Wire from
power
supply
7
IL1376
Wire from
motor
Pressure
switch
Strain
relief
6
6. Insert an electrical wire strain relief into the
opening in the opposite side of the pressure
switch.
7. Thread the cable from the power supply through
the strain relief and tighten both screws on the
strain relief. Do not crush wire.
Wire
from
motor
Wire from
power
supply
Ground Screws
Green
ground
wire
9
Outside
terminal
Two wires
from power
supply
Outside
terminal
Wire from
motor
Wire from
power
supply
8
9. Connect the green ground wire from the power
supply to the remaining green ground screw in
the pressure switch, and re-attach the pressure
switch cover.
8. Connect the two wires from the power supply to
the two outside terminals on the pressure switch.