Typical Pump Setup
Thconvertible jet pump is designed for use in these
applications:
1. Shallow wells (0 - 25 ft. lift) where ejector bolts to
pump.
(FOR WELL DEPTHS OVER 25 FT., SEE
INSTRUCTIONS 024990)
IL2137
Water Level
25 ft.
Max
Suction
Lift
3/4 in.
Discharge Pipe
1-1/4 in.
Suction
Pipe
Discharge
to Home
Pipe
Support
Foot Valve
1
Water Level
25 ft.
Maximum
Suction
Lift
Foot Valve
5 Ft. Minimum
1
1. Attach foot valve to the end of the suction pipe
and set in the well, making certain the valve is
below the water level. The foot valve should be
at least five (5) feet from the bottom of the well to
prevent sand from being drawn into the system.
IL2125
Water level
Slope pipe
upward
Pipe
support
Unions
Foot valve
3
1-1/4 in.
Suction
Pipe
Check
Valve
2
3. All piping from the well to the pump should slope
slightly upward with no sagging. Support suction
pipe between water source and pump. Unions in
the suction line near the pump and well will aid in
servicing. Be sure to leave enough room so that
wrenches can be used easily.
2. When connecting a drive point, a check valve
must be used in the suction line in place of a foot
valve. For easy priming, install the check valve as
close to the well as possible.
INSTALLING PIPING IN WELL - SHALLOW WELL