Power supply required .........................................................................................115 volts or 230 volts, 60 Hz
(Pump is set by the factory to run on 230 volts)
Maximum water temperature .........................................................................................................77°F (25°C)
Individual branch circuit required .......................................................................................... 15 Amp minimum
Discharge connection ........................................................................................................................1 in. NPT
Suction connection ......................................................................................................................1-1/4 in. NPT
Motor duty....................................Continuous duty with enforced air cooling and thermal overload protection
Pressure switch .........................................................................................
Preset at 20 PSI “on” / 40 PSI “off”
Water depth rating - Deep Well ............................................................................................ Maximum of 70 ft
ITEM #
HP VOLTAGE HZ MAX
AMPS
LOCKED
ROTOR
AMPS
PERFORMANCE AT 40 PSI - GPM
DEEP WELL
30 FT 40 FT 50 FT 60 FT 70 FT
1463-0006
1
115/230
60
14/7
52/26
10.6
7.9
7.3
5.7
4.6
• ELECTRICAL SHOCK HAZARD.
Always disconnect power source before performing any work on or near the motor or its connected load.
If the power disconnect point is out-of-sight, lock it in the open position and tag it to prevent unexpected
application of power. Failure to do so could result in fatal electrical shock.
• ELECTRICAL SHOCK HAZARD.
Do not handle the pump with wet hands or when standing in water as fatal electrical shock could occur.
Disconnect main power before handling unit for ANY REASON!
• RISK OF ELECTRIC SHOCK.
These pumps have not been investigated for use in swimming pool areas.
• ELECTRICAL SHOCK ALERT.
Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the
Occupational Safety and Health Act (OSHA).
• ELECTRICAL SHOCK ALERT.
Replace damaged or worn wiring cord immediately. Never use an extension cord.
• ELECTRICAL SHOCK ALERT.
Do not kink power cable and never allow the cable to come in contact with oil, grease, hot surfaces, or
chemicals.
• ELECTRICAL SHOCK ALERT.
Wire motor to correct supply voltage. This pump has a dual voltage motor and can run on 115 V or 230 V. It
is factory pre-set to run on 230 V.
• ELECTRICAL SHOCK ALERT.
SAFETY INFORMATION
Please read and understand this entire manual before attempting to assemble, operate, or install the
product.
• NOTE:
Pumps with the “UL” Mark and pumps with the “US” mark are tested to UL Standard UL778.
CSA certified pumps are certified to CSA Standard C22.2 No. 108. (CUS.)
DANGER
WARNING
PRODUCT SPECIFICATIONS