6
❶ Installation
1.1 I Selecting the location
1.1.1 Installation precautions
•
The appliance should be installed at a distance of at least 2 metres from the edge of the pool.
•
Do not lift the appliance by the body; use its base.
•
The appliance can only be installed outdoors : provide free space around it (see § “1.1.2 Selecting the location”).
•
Place the appliance on its anti-vibration pads (supplied with appliance) on a stable, solid and level surface.
•
The surface must be able to bear the weight of the appliance (in particular in the case of installation on a roof, a
balcony or any other support).
•
The appliance may be secured to the ground using the holes in the base of the appliance or with rails (not supplied).
: Front
: Rear
: Anti-vibration pads
View of the appliance base from below for installing the anti-vibration pads
The appliance must not be installed:
•
In a closed and unventilated room,
•
In a location where it would be subject to snow build-up,
•
In a location where it might be flooded by the condensates produced by the appliance when operating.
•
In a location subject to high winds,
•
With the blowing towards a permanent or temporary obstacle (awning, brushwood, etc.) less than
2,5 metres away,
•
On brackets,
•
Within range of water or mud jets, sprays or run-off (take the effect of the wind into account),
•
Near a heat source or flammable gas,
•
Near high-frequency equipment,
Tip: to reduce noise produced by your heat pump
•
Do not install it under or facing a window.
•
Do not tilt it towards your neighbours.
•
Install the appliance in an open space (sound waves are reflected on surfaces).
•
Install an acoustic screen around the heat pump, respecting the distances (see § “1.2 I Hydraulic
connections”).
•
Install 50cm of flexible PVC pipe at the heat pump water inlet and outlet (to stop vibrations).