H03620
‐
00.B5.EN
–
2011/11
8
if
the
heat
pump
is
on
stand
‐
by:
,
press
on
for
3
seconds,
will
appear
for
2
seconds,
and
for
3
seconds,
and
the
water
and
set
‐
point
temperatures
will
be
displayed:
,
a
2
‐
minute
delay
will
start,
set
the
required
water
temperature:
-
press
to
increase
temperature,
-
press
to
decrease
temperature,
When
the
pool
reaches
the
required
temperature,
the
heat
pump
will
automatically
stop.
set
the
water
flow
‐
rate
using
the
menu
,
when
the
indicator
is
steady:
press
to
display
the
water
flow
‐
rate
status:
Status
water
flow
‐
rate
ok
no
water
flow
water
flow
‐
rate
too
weak
water
flow
‐
rate
too
strong
Display
set
the
flow
‐
rate
using
valve
5
(or
3
if
no
valve
5
is
fitted),
and,
to
quit
the
menu,
press
.
During
this
adjustment
phase,
wait
for
a
few
minutes
after
each
change
in
valve
position
to
allow
the
device
to
balance.
3.3
Checks
to
perform
after
start
‐
up
The
heat
pump
must
stop
when:
the
set
‐
point
temperature
is
lowered
using
the
digital
control
panel,
filtering
is
stopped
or
valve
2
or
3
is
closed
3,
the
digital
control
panel
is
turned
off
by
pressing
,
3.4
Winter
storage
Winter
storage
is
essential
due
to
the
risk
of
the
condenser
freezing
and
breaking.
This
situation
is
not
covered
by
the
warranty.
To
avoid
damaging
the
device
with
condensation,
do
not
cover
it
with
an
air
‐
tight
cover.
switch
the
digital
control
panel
to
"stand
‐
by"
mode
by
pressing
for
3
seconds,
and
cut
the
power
supply,
open
valve
1,
close
valves
2
and
3,
and
open
valves
4
and
5
(if
fitted),
ensure
that
no
water
is
flowing
through
the
heat
pump,
drain
the
water
condenser
by
unscrewing
the
two
pool
water
inlet
and
outlet
connections
at
the
back
of
the
heat
pump,
in
the
case
of
full
winter
storage
conditions
for
the
pool:
re
‐
connect
the
inlet
and
outlet
connections
to
avoid
foreign
bodies
entering
into
the
condenser,
in
the
case
of
winter
storage
for
the
heat
pump
alone:
do
not
reconnect
the
inlet
and
outlet
connectors,
instead
place
two
plugs
(supplied)
on
the
condenser
water
inlet
and
outlet.
cover
the
heat
pump
with
a
micro
‐
breathing
overwintering
cover
(optional
accessory,
see
§4.3).
4.
Maintenance
4.1
Maintenance
instructions
It
is
recommended
that
the
device
be
general
serviced
on
a
yearly
basis
to
ensure
proper
operation,
maintain
performance
levels
and
prevent
some
potential
failures.
This
is
the
responsibility
of
the
user
and
must
be
performed
by
a
qualified
technician.
Do
not
use
a
high
‐
pressure
water
hose.
Содержание PF Premium 6M
Страница 15: ...Notes ...
Страница 16: ...H03620 00 B5 EN 2011 11 1 Wiring diagram PFP 6M 8M 11M 13M ...
Страница 17: ...H03620 00 B5 EN 2011 11 2 PFP 11T ...
Страница 18: ...H03620 00 B5 EN 2011 11 3 PFP 11M TSR 15M TSR ...
Страница 19: ...H03620 00 B5 EN 2011 11 4 PFP 11T TSR 15T TSR ...