H03620
‐
00.B5.EN
–
2011/11
12
Dysfunction
Causes
Verification
/
solution
the
heat
pump
makes
trip
the
circuit
breaker
The
circuit
breaker
rating
is
too
low
or
inappropriate
Check
the
circuit
breaker
(see
§
2.5.3).
The
cable
cross
‐
section
is
too
small
Check
the
cable
cross
‐
section
(see
§
2.5.3)
The
supply
voltage
is
too
low
Call
your
electricity
provider
5.3
FAQ
Is
it
possible
to
improve
temperature
performance?
In
order
to
improve
the
efficiency
of
your
heat
pump
it
is
recommende
d
that
you:
protect
the
pool
with
a
cover
(floating
cover,
roller
cover,
etc.),
to
avoid
heat
loss
choose
periods
when
the
outside
temperature
is
warm
(on
average
>
10°
C)
in
order
to
facilitate
the
temperature
increase
(this
may
take
several
days.
The
actual
time
will
vary
according
to
weather
conditions
and
the
power
of
the
heat
pump)
the
higher
the
ambient
air
temperature,
the
more
efficient
the
heat
pump
will
be
keep
the
evaporator
clean
Check
that
filtration
time
is
sufficient
during
the
heating
phase,
water
flow
must
be
continuous
(24/24)
to
maintain
the
temperature
throughout
the
season,
allow
for
“automatic”
flow
of
at
least
12
hours/day
(the
longer
automatic
flow
is
used,
the
more
time
the
heat
pump
will
have
to
function
and
to
heat
the
water)
Setting
the
set
‐
point
to
maximum
will
not
heat
the
water
any
faster
Why
is
my
heat
pump
not
heating?
on
start
‐
up
the
device
remains
on
“pause”
for
3
minutes
before
actually
starting
up:
check
that
this
period
has
passed
once
the
pool
has
reached
the
set
‐
point
temperature,
the
heat
pump
switches
off:
check
that
the
water
temperature
is
lower
than
the
requested
temperature
(see
§3.2)
if
the
water
flow
‐
rate
is
zero
or
inadequate,
the
heat
pump
will
stop:
check
that
water
is
flowing
correctly
through
the
heat
pump,
and
check
the
hydraulic
connections
when
the
outdoor
air
temperature
drops
below
‐
12
°C,
the
heat
pump
will
stop:
check
the
outdoor
temperature
the
heat
pump
may
have
detected
a
malfunction:
check
if
an
error
code
is
displayed
on
the
screen,
if
so
refer
to
§5.1
If
the
problem
persists
after
you
have
checked
all
of
the
above
points:
contact
your
installer
Where
should
my
water
treatment
system
be
positioned
with
respect
to
the
heating
system?
The
water
treatment
system
(chlorinator,
salt
chlorinator,
etc.)
must
be
installed
preferably
downstream
from
the
heat
pump
(see
installation
§2.4),
and
must
be
compatible
with
the
latter
(check
with
the
manufacturer)
The
heat
pump
is
giving
off
water:
is
this
normal?
Your
heat
pump
will
give
off
water
in
the
form
of
condensation.
This
water
is
the
humidity
contained
in
the
air,
which
condenses
on
contact
with
certain
cold
components
inside
the
heat
pump.
Warning:
your
device
can
produce
several
litres
of
water
per
day.
6.
Product
registration
Register
your
product
using
our
website:
-
you
will
be
among
the
first
to
be
informed
of
new
Zodiac
products
and
special
offers,
-
You
can
help
us
to
constantly
improve
our
product
quality.
Australia
–
New
Zealand
www.zodiac.com.au
South
Africa
www.zodiac.co.za
Europe
and
rest
of
the
world
www.zodiac
‐
poolcare.com
Содержание PF Premium 6M
Страница 15: ...Notes ...
Страница 16: ...H03620 00 B5 EN 2011 11 1 Wiring diagram PFP 6M 8M 11M 13M ...
Страница 17: ...H03620 00 B5 EN 2011 11 2 PFP 11T ...
Страница 18: ...H03620 00 B5 EN 2011 11 3 PFP 11M TSR 15M TSR ...
Страница 19: ...H03620 00 B5 EN 2011 11 4 PFP 11T TSR 15T TSR ...