Zodiac PF Premium 6M Скачать руководство пользователя страница 12

H03620

00.B5.EN

 

 

2011/11

 

 

11

 

Display

 

Designation

 

Cause

 

Solution

 

Reset

 

 

Water

 

flow

rate

 

sensor

 

defect

 

(ST4)

 

Sensor

 

out

of

order

 

or

 

disconnected

 

(connector

 

J8

 

white

 

on

 

plate

 

A1)

 

Replace

 

or

 

reconnect

 

the

 

sensor

 

Switch

 

the

 

power

 

supply

 

off

 

or

 

automatic

 

reset

 

if

 

the

 

defect

 

disappears

 

 

Defrost

 

sensor

 

defect

 

(ST3)

 

Sensor

 

out

of

order

 

or

 

disconnected

 

(terminals

 

1

2

 

of

 

connector

 

J3

 

white

 

on

 

plate

 

A2)

 

Replace

 

or

 

reconnect

 

the

 

sensor

 

Switch

 

the

 

power

 

supply

 

off

 

or

 

press

 

 

 

Anti

freeze

 

sensor

 

defect

 

(ST2)

 

Sensor

 

out

of

order

 

or

 

disconnected

 

(terminals

3

4

 

of

 

connector

 

J3

 

white

 

on

 

plate

 

A2)

 

Replace

 

or

 

reconnect

 

the

 

sensor

 

Switch

 

the

 

power

 

supply

 

off

 

or

 

press

 

 

 

Compressor

 

discharge

 

sensor

 

defect

 

(ST5)

 

Sensor

 

out

of

order

 

or

 

disconnected

 

(connector

 

J7

 

black

 

on

 

plate

 

A1)

 

Replace

 

or

 

reconnect

 

the

 

sensor

 

Switch

 

the

 

power

 

supply

 

off

 

or

 

automatic

 

reset

 

if

 

the

 

defect

 

disappears.

 

 

Communications'

 

defect

 

between

 

the

 

main

 

card

 

A1

 

and

 

the

 

display

 

card

 

A2

 

1.

 

Incorrect

 

connection

 

between

 

plates

 

A1

 

and

 

A2

 

2.

 

Card

 

supply

 

defect

 

3.

 

Cards

 

out

 

of

 

order

 

1

 

and

 

2.

 

Check

 

connections

 

(connectors

 

J8

 

and

 

J9

 

yellow,

 

and

 

J7

 

and

 

J4

J5

 

black)

  

1,

 

2

 

and

 

3.

 

if

 

the

 

defect

 

persists,

 

contact

 

an

 

approved

 

technician

  

Switch

 

the

 

power

 

supply

 

off

 

or

 

automatic

 

reset

 

if

 

the

 

defect

 

disappears

 

 

5.2

 

Malfunctions

 

of

 

the

 

device

 

 

Dysfunction

 

Causes

 

Verification

 

/

 

solution

 

The

 

device

 

is

 

not

 

operational

 

No

 

display

 

Check

 

the

 

supply

 

voltage

 

and

 

the

 

fuse

 

F1

  

The

 

pool

 

temperature

 

is

 

above

 

the

 

set

point

 

temperature

 

Increase

 

the

 

set

point

 

temperature

 

A

 

message

 

is

 

displayed

 

on

 

the

 

screen

 

Check

 

the

 

meaning

 

of

 

message

 

§5.1

 

Absent

 

or

 

inadequate

 

water

 

flow

rate

 

Check

 

the

 

water

 

flow

rate

 

(by

pass,

 

filtration)

 

The

 

device

 

is

 

operational,

 

but

 

water

 

temperature

 

fails

 

to

 

rise

 

Inadequate

 

filtering

 

time

 

Set

 

the

 

filtering

 

system

 

to

 

manual

 

24

‐ 

hour

 

operation

 

for

 

temperature

 

control

 

Non

compliant

 

period

 

of

 

use

 

Check

 

that

 

outdoor

 

temperature

 

is

 

within

 

the

 

operating

 

range

 

(see

 

§1.3)

 

The

 

heat

 

pump

 

is

 

under

dimensioned

 

Check

 

the

 

characteristics

 

of

 

the

 

heat

 

pump

 

according

 

to

 

the

 

pool

 

The

 

automatic

 

pool

 

water

 

filler

 

is

 

blocked

 

in

 

the

 

open

 

position

 

Check

 

the

 

correct

 

operation

 

of

 

the

 

automatic

 

filler

 

The

 

heat

 

insulating

 

cover

 

is

 

not

 

used

 

Fit

 

the

 

heat

 

insulating

 

cover

 

The

 

evaporator

 

is

 

clogged

 

Clean

 

the

 

evaporator

 

(see

 

§4.1)

 

The

 

device

 

is

 

incorrectly

 

installed

 

The

 

device

 

must

 

be

 

installed

 

outdoors.

 

Check

 

that

 

there

 

is

 

no

 

obstacle

 

less

 

than

 

4

 

metres

 

from

 

where

 

the

 

blower

 

is

 

facing,

 

and

 

0.50

 

metres

 

behind

 

the

 

heat

 

pump.

 

A

 

message

 

is

 

displayed

 

on

 

the

 

screen

 

Check

 

the

 

meaning

 

of

 

message

 

§5.1

 

The

 

fan

 

is

 

turning,

 

but

 

the

 

compressor

 

stops

 

from

 

time

 

to

 

time

 

without

 

an

 

error

 

message

 

appearing

 

The

 

heat

 

pump

 

does

 

defrost

 

cycles

 

from

 

time

 

to

 

time

 

This

 

is

 

normal

 

if

 

the

 

outdoor

 

temperature

 

is

 

below

 

10

 

°C

 

The

 

evaporator

 

is

 

clogged

 

Clean

 

the

 

evaporator

 

(see

 

§4.1)

 

 
 
 

Содержание PF Premium 6M

Страница 1: ...EN PF Premium 11M TSR 11T TSR 15M TSR 15T TSR 6M 8M 11M 11T 13M Instructions for installation and use English H03620 00 B 2011 11 374274014 00 More languages on www zodiac poolcare com ...

Страница 2: ...personnel physically and mentally who are familiar with the operating instructions by reading the user guide Persons who do not satisfy these requirements must not handle the device so as to avoid exposure to potentially dangerous parts If the device malfunctions do not attempt to repair the device yourself call your installer Before carrying out any operation on the machine check that the power s...

Страница 3: ...lay of the regulator 10 5 2 Malfunctions of the device 11 5 3 FAQ 12 6 Product registration 12 7 Conformity certificate 13 Available in appendix at the end of the manual wiring diagrams dimensions description 1 Information before installation 1 1 General terms of delivery storage and transport Any equipment even carriage and packing free travels at the consignee s risk The consignee shall make res...

Страница 4: ...midity of 70 according to French standard NF 414 protection class IP 24 refrigerant gas R410A refrigerant charge see product information plate class I degree of pollution 2 overvoltage category II 2 Installation Do not pick up the device using the outer casing use the base 2 1 Access to the technical compartment 2 2 Selecting an installation site The device must be installed outdoors and there mus...

Страница 5: ... Hydraulic connections Check the direction of the pipework connection see Dimensions in the appendix The connection shall comprise a Ø 50 PVC rigid pipe from a by pass on the swimming pool filtration circuit after the filter and before any water treatment unit check the tightening of the hydraulic connections and for leaks PFP Hydraulic circuit pressure Connections inlet outlet Mean water flowrate...

Страница 6: ...tside of the European community and with an outer diameter between 9 and 18 mm use the stuffing box to run the supply cable into the device 2 5 2 Connections the electrical supply cable must not be exposed to elements that are sharp hot or represent a crush hazard check that all cables are secure and all terminal connections are correct Loose terminals may cause the supply terminal board to overhe...

Страница 7: ...minals 1 2 alarm option to connect a relay to the alarm contact thanks to a dry contact without max I polarity 2 A between terminals 5 6 remote on off control thanks to a zero potential free contact without 230 V 50 Hz polarity between terminals 7 8 3 Use 3 1 Presentation of the regulation Symbol Designation steady flashing water flow water flow rate ok water flow too weak high or absent ambient a...

Страница 8: ...echnical components must be fitted set the by pass and setting valves see 2 4 as follows valve 1 completely open valves 2 3 4 5 closed The incorrect setting of the by pass valve can lead to the malfunctioning of the heat pump switch on the filter system progressively close valve 1 in order to increase the filter pressure to 150 g 0 150 bar open valves 2 3 and 4 completely then half open valve 5 se...

Страница 9: ...sential due to the risk of the condenser freezing and breaking This situation is not covered by the warranty To avoid damaging the device with condensation do not cover it with an air tight cover switch the digital control panel to stand by mode by pressing for 3 seconds and cut the power supply open valve 1 close valves 2 and 3 and open valves 4 and 5 if fitted ensure that no water is flowing thr...

Страница 10: ... they are securely fastened to the coolant circuit and that they cutoff the electrical circuit when tripped during maintenance work ensure there are no traces of corrosion or oil around cooling components before beginning work on the cooling circuit stop the device and wait for a few minutes before fitting the temperature and pressure sensors Some elements such as the compressor and piping may rea...

Страница 11: ... several phases 1 reverse the phases on the supply terminal board without power to the device 2 3 4 contact your electricity provider to find out if modifications have been made to your equipment Switch the power supply off or press Refrigerant circuit low pressure defect Low pressure circuit pressure defect if the defect remains after reset Contact an approved technician Automatic reset for less ...

Страница 12: ...Verification solution The device is not operational No display Check the supply voltage and the fuse F1 The pool temperature is above the set point temperature Increase the set point temperature A message is displayed on the screen Check the meaning of message 5 1 Absent or inadequate water flow rate Check the water flow rate by pass filtration The device is operational but water temperature fails...

Страница 13: ...eck that this period has passed once the pool has reached the set point temperature the heat pump switches off check that the water temperature is lower than the requested temperature see 3 2 if the water flow rate is zero or inadequate the heat pump will stop check that water is flowing correctly through the heat pump and check the hydraulic connections when the outdoor air temperature drops belo...

Страница 14: ... following products or ranges Swimming pool heat pumps Power First Premium 6M 8M 11M 11T 13M Power First Premium 11M TSR 11T TSR 15M TSR 15T TSR are in compliance with the provisions of the ELECTROMAGNETIC COMPATIBILITY directive 2004 108 EC the LOW VOLTAGE directive 2006 95 EC ...

Страница 15: ...Notes ...

Страница 16: ...H03620 00 B5 EN 2011 11 1 Wiring diagram PFP 6M 8M 11M 13M ...

Страница 17: ...H03620 00 B5 EN 2011 11 2 PFP 11T ...

Страница 18: ...H03620 00 B5 EN 2011 11 3 PFP 11M TSR 15M TSR ...

Страница 19: ...H03620 00 B5 EN 2011 11 4 PFP 11T TSR 15T TSR ...

Страница 20: ...oard for display C1 Fan capacitor C2 Compressor capacitor C3 Filter D1 Progressive starter H Defrost resistance HP High pressure switch LP Low pressure switch J1 Flow rate switch M1 Fan motor M2 Compressor motor MOV Expansion valve PHC Phase order controler R1 R2 Contactor ST1 Regulator sensor ST2 Anti freeze sensor ST3 Defrost sensor ST4 Liquid line sensor ST5 Compressor discharge sensor VA1 VA2 ...

Страница 21: ...N 2011 11 6 Dimensions and description Base Front pannel cowl Technical door Back pannel Post Grid Regulator Ø1 water pool inlet Ø1 water pool outlet Evaporator Stuffing box PFP weight Kg 6 51 8 52 11 63 13 68 15 81 ...

Страница 22: ...ct your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer Zodiac pool Care Europe BP 90023 49180 St Barthélémy d Anjou cedex France S A S U au capital de 517 200 SIREN 395 068 679 RCS PARIS Plaque signalétique Product name plate ...

Отзывы: