H03620
‐
00.B5.EN
–
2011/11
11
Display
Designation
Cause
Solution
Reset
Water
flow
‐
rate
sensor
defect
(ST4)
Sensor
out
‐
of
‐
order
or
disconnected
(connector
J8
white
on
plate
A1)
Replace
or
reconnect
the
sensor
Switch
the
power
supply
off
or
automatic
reset
if
the
defect
disappears
Defrost
sensor
defect
(ST3)
Sensor
out
‐
of
‐
order
or
disconnected
(terminals
1
‐
2
of
connector
J3
white
on
plate
A2)
Replace
or
reconnect
the
sensor
Switch
the
power
supply
off
or
press
Anti
‐
freeze
sensor
defect
(ST2)
Sensor
out
‐
of
‐
order
or
disconnected
(terminals
3
‐
4
of
connector
J3
white
on
plate
A2)
Replace
or
reconnect
the
sensor
Switch
the
power
supply
off
or
press
Compressor
discharge
sensor
defect
(ST5)
Sensor
out
‐
of
‐
order
or
disconnected
(connector
J7
black
on
plate
A1)
Replace
or
reconnect
the
sensor
Switch
the
power
supply
off
or
automatic
reset
if
the
defect
disappears.
Communications'
defect
between
the
main
card
A1
and
the
display
card
A2
1.
Incorrect
connection
between
plates
A1
and
A2
2.
Card
supply
defect
3.
Cards
out
of
order
1
and
2.
Check
connections
(connectors
J8
and
J9
yellow,
and
J7
and
J4
‐
J5
black)
1,
2
and
3.
if
the
defect
persists,
contact
an
approved
technician
Switch
the
power
supply
off
or
automatic
reset
if
the
defect
disappears
5.2
Malfunctions
of
the
device
Dysfunction
Causes
Verification
/
solution
The
device
is
not
operational
No
display
Check
the
supply
voltage
and
the
fuse
F1
The
pool
temperature
is
above
the
set
‐
point
temperature
Increase
the
set
‐
point
temperature
A
message
is
displayed
on
the
screen
Check
the
meaning
of
message
§5.1
Absent
or
inadequate
water
flow
‐
rate
Check
the
water
flow
‐
rate
(by
‐
pass,
filtration)
The
device
is
operational,
but
water
temperature
fails
to
rise
Inadequate
filtering
time
Set
the
filtering
system
to
manual
24
‐
hour
operation
for
temperature
control
Non
‐
compliant
period
of
use
Check
that
outdoor
temperature
is
within
the
operating
range
(see
§1.3)
The
heat
pump
is
under
‐
dimensioned
Check
the
characteristics
of
the
heat
pump
according
to
the
pool
The
automatic
pool
water
filler
is
blocked
in
the
open
position
Check
the
correct
operation
of
the
automatic
filler
The
heat
insulating
cover
is
not
used
Fit
the
heat
insulating
cover
The
evaporator
is
clogged
Clean
the
evaporator
(see
§4.1)
The
device
is
incorrectly
installed
The
device
must
be
installed
outdoors.
Check
that
there
is
no
obstacle
less
than
4
metres
from
where
the
blower
is
facing,
and
0.50
metres
behind
the
heat
pump.
A
message
is
displayed
on
the
screen
Check
the
meaning
of
message
§5.1
The
fan
is
turning,
but
the
compressor
stops
from
time
to
time
without
an
error
message
appearing
The
heat
pump
does
defrost
cycles
from
time
to
time
This
is
normal
if
the
outdoor
temperature
is
below
10
°C
The
evaporator
is
clogged
Clean
the
evaporator