5.
Resolution
of
problem
5.1
Display
of
the
regulator
Display
Designation
Cause
Solution
Reset
Cold
protection
of
heat
exchanger
Low
temperature
inside
heat
exchanger
Wait
the
heat
exhanger
come
normal
temperature
Automatic
High
temperature
defect
for
the
air
heat
exchanger
in
"cooling"
mode
Temperature
probe
ST3
above
60°C
if
the
defect
persists,
contact
an
approved
technician
Automatic
if
temperature
probe
ST3
is
below
45°C
Phase
order
defect
(only
on
three
‐
phased
models)
1.
wiring
incorrect
on
the
supply
terminal
board
of
the
device,
2.
modification
of
phase
order
by
electrical
supplier,
3.
temporary
failure
of
one
or
several
phases
1.
reverse
the
phases
on
the
supply
terminal
board
(without
power
to
the
device)
2,
3,
4.
contact
your
electricity
provider
to
find
out
if
modifications
have
been
made
to
your
equipment.
Switch
the
power
supply
off
or
press
Refrigerant
circuit
low
pressure
defect
Low
pressure
circuit
pressure
defect
(if
the
defect
remains
after
reset)
Contact
an
approved
technician
Automatic
reset
(for
less
than
4
defects
per
hour)
or
press
Refrigerant
circuit
high
pressure
defect
1.
water
and
air
mixture
passing
in
the
appliance,
2.
unsatisfactory
water
flow,
3.
blocked
flow
controller
4.
clogged
or
blocked
heat
exchanger
1.
check
the
pool
hydraulic
circuit
2.
increase
the
flow
‐
rate
using
the
by
‐
pass,
check
that
the
pool
filter
is
not
clogged)
3.
check
the
flow
‐
rate
controller
4.
clean
the
exchanger
5.
if
the
defect
persists,
contact
an
approved
technician
Automatic
reset
(for
less
than
4
defects
per
hour)
or
press
Compressor
discharge
temperature
defect
Compressor
discharge
temperature
too
high
contact
an
approved
technician
press
for
3
seconds
Control
sensor
defect
(ST1)
Sensor
out
‐
of
‐
order
or
disconnected
(connector
J2
red
on
plate
A1)
Replace
or
reconnect
the
sensor
Switch
the
power
supply
off
or
press