H03620
‐
00.B5.EN
–
2011/11
7
Symbol
Designation
steady
flashing
defrost
indicator
Defrost
in
progress
/
On/off
button
button
to
set
and
confirm
parameters
value
setting
buttons
3.1.1
Reading
and
changing
parameters
3.1.2
Locking
and
releasing
the
key
pad
Press
and
for
3
seconds:
or
3.2
Starting
the
device
check
that
no
tools
or
other
objects
have
been
left
inside
the
device,
the
access
door
for
technical
components
must
be
fitted,
set
the
by
‐
pass
and
setting
valves
(see
§
2.4)
as
follows:
-
valve
1
completely
open,
-
valves
2
‐
3
‐
4
&
5
closed.
The
incorrect
setting
of
the
by
‐
pass
valve
can
lead
to
the
malfunctioning
of
the
heat
pump.
switch
on
the
filter
system,
progressively
close
valve
1
in
order
to
increase
the
filter
pressure
to
150
g
(0.150
bar)
,
open
valves
2,
3
and
4
completely,
then
half
open
valve
5
(see
§2.4)
(the
air
accumulated
in
the
heat
pump
condenser
and
in
the
filter
circuit
is
then
bled),
If
valves
4
and
5
are
not
fitted,
open
valve
1
completely,
and
half
close
valve
3.
power
‐
up
the
heat
pump,