background image

H03620

00.B5.EN

 

 

2011/11

 

 

9

 

 

ensure

 

no

 

foreign

 

bodies

 

obstruct

 

the

 

fan

 

grid.

 

 

clean

 

the

 

evaporator

 

with

 

a

 

soft

 

brush

 

and

 

a

 

fresh

 

water

 

jet

 

(disconnect

 

the

 

power

 

cable),

 

do

 

not

 

twist

 

or

 

bend

 

the

 

metal

 

blades,

 

then

 

to

 

clean

 

the

 

discharge

 

pipe

 

of

 

the

 

condensates

 

in

 

order

 

to

 

evacuate

 

the

 

impurities

 

which

 

could

 

block

 

it,

 

 

clean

 

the

 

outside

 

of

 

the

 

unit

 

with

 

a

 

solvent

free

 

product.

 

A

 

specific

 

PAC

 

NET

 

cleaning

 

kit

 

is

 

available

 

as

 

an

 

optional

 

extra

 

(see

 

§4.3),

 

 

check

 

that

 

the

 

water

 

condensation

 

flows

 

out

 

properly

 

during

 

the

 

operation

 

of

 

the

 

device.

 

 

check

 

the

 

proper

 

operation

 

of

 

the

 

regulator,

  

 

check

 

electrical

 

components,

 

 

check

 

that

 

all

 

metal

 

elements

 

are

 

grounded,

 

 

check

 

the

 

tightening

 

and

 

connections

 

of

 

electric

 

cables

 

and

 

the

 

cleanliness

 

of

 

the

 

electrical

 

compartment.

 

 

4.2

 

Additional

 

recommendations

 

in

 

relation

 

to

 

the

 

Pressure

 

Equipment

 

Directive

 

(PED

97/23/CE)

 

 

4.2.1

 

Installation

 

and

 

maintenance

 

 

 

the

 

unit

 

may

 

not

 

be

 

installed

 

close

 

to

 

combustible

 

materials,

 

or

 

the

 

air

 

duct

 

inlet

 

of

 

an

 

adjacent

 

building

 

.

 

 

with

 

some

 

devices,

 

it

 

is

 

essential

 

to

 

fit

 

protection

 

grids

 

if

 

the

 

unit

 

is

 

installed

 

in

 

an

 

area

 

with

 

uncontrolled

 

access.

 

 

during

 

installation,

 

troubleshooting

 

and

 

maintenance,

 

pipes

 

may

 

not

 

be

 

used

 

as

 

steps:

 

the

 

pipe

 

could

 

break

 

under

 

the

 

weight,

 

spilling

 

refrigerant

 

and

 

possibly

 

causing

 

serious

 

burns.

 

 

when

 

servicing

 

the

 

appliance,

 

the

 

composition

 

and

 

state

 

of

 

heat

 

carrying

 

fluid

 

must

 

be

 

checked,

 

as

 

well

 

as

 

the

 

absence

 

of

 

any

 

refrigerant.

 

 

during

 

the

 

annual

 

unit

 

sealing

 

test

 

in

 

accordance

 

with

 

applicable

 

legislation,

 

the

 

high

 

and

 

low

 

pressure

 

switches

 

must

 

be

 

checked

 

to

 

ensure

 

that

 

they

 

are

 

securely

 

fastened

 

to

 

the

 

coolant

 

circuit

 

and

 

that

 

they

 

cutoff

 

the

 

electrical

 

circuit

 

when

 

tripped.

 

 

during

 

maintenance

 

work,

 

ensure

 

there

 

are

 

no

 

traces

 

of

 

corrosion

 

or

 

oil

 

around

 

cooling

 

components.

 

 

before

 

beginning

 

work

 

on

 

the

 

cooling

 

circuit,

 

stop

 

the

 

device

 

and

 

wait

 

for

 

a

 

few

 

minutes

 

before

 

fitting

 

the

 

temperature

 

and

 

pressure

 

sensors.

 

Some

 

elements

 

such

 

as

 

the

 

compressor

 

and

 

piping

 

may

 

reach

 

temperatures

 

in

 

excess

 

of

 

100°C

 

and

 

high

 

pressures

 

with

 

the

 

consequent

 

risk

 

of

 

severe

 

scalding.

  

 

4.2.2

 

Troubleshooting

 

 

 

all

 

soldering

 

work

 

must

 

be

 

carried

 

out

 

by

 

a

 

someone

 

qualified

 

to

 

do

 

so.

 

 

replacement

 

pipes

 

must

 

always

 

be

 

made

 

of

 

copper

 

in

 

compliance

 

with

 

standard

 

NF

 

EN

 

12735

1.

 

 

leak

 

detection;

 

pressure

 

test:

 

-

 

never

 

use

 

oxygen

 

or

 

dry

 

air,

 

risk

 

of

 

fire

 

or

 

explosion,

  

-

 

use

 

dry

 

nitrogen

 

or

 

the

 

mixture

 

of

 

nitrogen

 

and

 

refrigerant

 

indicated

 

on

 

the

 

information

 

plate,

  

-

 

the

 

test

 

pressure

 

for

 

both

 

the

 

high

 

and

 

low

 

pressure

 

circuits

 

must

 

not

 

exceed

 

42

 

bar.

 

 

the

 

high

 

pressure

 

circuit

 

pipes

 

are

 

made

 

of

 

copper

 

and

 

have

 

a

 

diameter

 

equal

 

to

 

or

 

greater

 

than

 

1’’5/8.

 

A

 

certificate

 

as

 

indicated

 

in

 

§2.1

 

in

 

compliance

 

with

 

standard

 

NF

 

EN

 

10204

 

will

 

be

 

requested

 

from

 

the

 

supplier

 

and

 

filed

 

in

 

installation

 

technical

 

documentation.

 

 

technical

 

data

 

relative

 

to

 

the

 

safety

 

requirements

 

of

 

the

 

various

 

applicable

 

directives

 

must

 

be

 

indicated

 

on

 

the

 

information

 

plate.

  

 

This

 

data

 

must

 

be

 

recorded

 

in

 

the

 

installation

 

instructions

 

for

 

the

 

device

 

which

 

are

 

included

 

in

 

the

 

installation

 

technical

 

file

:

 

model,

 

code,

 

serial

 

number,

 

maximum

 

and

 

minimum

 

OT,

 

OP,

 

year

 

of

 

manufacture,

 

EC

 

label,

 

manufacturer’s

 

address,

 

refrigerant

 

and

 

weight,

 

electrical

 

parameters,

 

thermo

dynamic

 

and

 

acoustic

 

performances.

 

 

4.3

 

Available

 

accessories

 

 

Name

 

PAC

 

NET

 

Wintering

 

cover

 

Representation

  

Item

 

code

 

WMA03491

 

W20HOUSSEPFIRST

 

 
 
 
 
 

Содержание PF Premium 6M

Страница 1: ...EN PF Premium 11M TSR 11T TSR 15M TSR 15T TSR 6M 8M 11M 11T 13M Instructions for installation and use English H03620 00 B 2011 11 374274014 00 More languages on www zodiac poolcare com ...

Страница 2: ...personnel physically and mentally who are familiar with the operating instructions by reading the user guide Persons who do not satisfy these requirements must not handle the device so as to avoid exposure to potentially dangerous parts If the device malfunctions do not attempt to repair the device yourself call your installer Before carrying out any operation on the machine check that the power s...

Страница 3: ...lay of the regulator 10 5 2 Malfunctions of the device 11 5 3 FAQ 12 6 Product registration 12 7 Conformity certificate 13 Available in appendix at the end of the manual wiring diagrams dimensions description 1 Information before installation 1 1 General terms of delivery storage and transport Any equipment even carriage and packing free travels at the consignee s risk The consignee shall make res...

Страница 4: ...midity of 70 according to French standard NF 414 protection class IP 24 refrigerant gas R410A refrigerant charge see product information plate class I degree of pollution 2 overvoltage category II 2 Installation Do not pick up the device using the outer casing use the base 2 1 Access to the technical compartment 2 2 Selecting an installation site The device must be installed outdoors and there mus...

Страница 5: ... Hydraulic connections Check the direction of the pipework connection see Dimensions in the appendix The connection shall comprise a Ø 50 PVC rigid pipe from a by pass on the swimming pool filtration circuit after the filter and before any water treatment unit check the tightening of the hydraulic connections and for leaks PFP Hydraulic circuit pressure Connections inlet outlet Mean water flowrate...

Страница 6: ...tside of the European community and with an outer diameter between 9 and 18 mm use the stuffing box to run the supply cable into the device 2 5 2 Connections the electrical supply cable must not be exposed to elements that are sharp hot or represent a crush hazard check that all cables are secure and all terminal connections are correct Loose terminals may cause the supply terminal board to overhe...

Страница 7: ...minals 1 2 alarm option to connect a relay to the alarm contact thanks to a dry contact without max I polarity 2 A between terminals 5 6 remote on off control thanks to a zero potential free contact without 230 V 50 Hz polarity between terminals 7 8 3 Use 3 1 Presentation of the regulation Symbol Designation steady flashing water flow water flow rate ok water flow too weak high or absent ambient a...

Страница 8: ...echnical components must be fitted set the by pass and setting valves see 2 4 as follows valve 1 completely open valves 2 3 4 5 closed The incorrect setting of the by pass valve can lead to the malfunctioning of the heat pump switch on the filter system progressively close valve 1 in order to increase the filter pressure to 150 g 0 150 bar open valves 2 3 and 4 completely then half open valve 5 se...

Страница 9: ...sential due to the risk of the condenser freezing and breaking This situation is not covered by the warranty To avoid damaging the device with condensation do not cover it with an air tight cover switch the digital control panel to stand by mode by pressing for 3 seconds and cut the power supply open valve 1 close valves 2 and 3 and open valves 4 and 5 if fitted ensure that no water is flowing thr...

Страница 10: ... they are securely fastened to the coolant circuit and that they cutoff the electrical circuit when tripped during maintenance work ensure there are no traces of corrosion or oil around cooling components before beginning work on the cooling circuit stop the device and wait for a few minutes before fitting the temperature and pressure sensors Some elements such as the compressor and piping may rea...

Страница 11: ... several phases 1 reverse the phases on the supply terminal board without power to the device 2 3 4 contact your electricity provider to find out if modifications have been made to your equipment Switch the power supply off or press Refrigerant circuit low pressure defect Low pressure circuit pressure defect if the defect remains after reset Contact an approved technician Automatic reset for less ...

Страница 12: ...Verification solution The device is not operational No display Check the supply voltage and the fuse F1 The pool temperature is above the set point temperature Increase the set point temperature A message is displayed on the screen Check the meaning of message 5 1 Absent or inadequate water flow rate Check the water flow rate by pass filtration The device is operational but water temperature fails...

Страница 13: ...eck that this period has passed once the pool has reached the set point temperature the heat pump switches off check that the water temperature is lower than the requested temperature see 3 2 if the water flow rate is zero or inadequate the heat pump will stop check that water is flowing correctly through the heat pump and check the hydraulic connections when the outdoor air temperature drops belo...

Страница 14: ... following products or ranges Swimming pool heat pumps Power First Premium 6M 8M 11M 11T 13M Power First Premium 11M TSR 11T TSR 15M TSR 15T TSR are in compliance with the provisions of the ELECTROMAGNETIC COMPATIBILITY directive 2004 108 EC the LOW VOLTAGE directive 2006 95 EC ...

Страница 15: ...Notes ...

Страница 16: ...H03620 00 B5 EN 2011 11 1 Wiring diagram PFP 6M 8M 11M 13M ...

Страница 17: ...H03620 00 B5 EN 2011 11 2 PFP 11T ...

Страница 18: ...H03620 00 B5 EN 2011 11 3 PFP 11M TSR 15M TSR ...

Страница 19: ...H03620 00 B5 EN 2011 11 4 PFP 11T TSR 15T TSR ...

Страница 20: ...oard for display C1 Fan capacitor C2 Compressor capacitor C3 Filter D1 Progressive starter H Defrost resistance HP High pressure switch LP Low pressure switch J1 Flow rate switch M1 Fan motor M2 Compressor motor MOV Expansion valve PHC Phase order controler R1 R2 Contactor ST1 Regulator sensor ST2 Anti freeze sensor ST3 Defrost sensor ST4 Liquid line sensor ST5 Compressor discharge sensor VA1 VA2 ...

Страница 21: ...N 2011 11 6 Dimensions and description Base Front pannel cowl Technical door Back pannel Post Grid Regulator Ø1 water pool inlet Ø1 water pool outlet Evaporator Stuffing box PFP weight Kg 6 51 8 52 11 63 13 68 15 81 ...

Страница 22: ...ct your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer Zodiac pool Care Europe BP 90023 49180 St Barthélémy d Anjou cedex France S A S U au capital de 517 200 SIREN 395 068 679 RCS PARIS Plaque signalétique Product name plate ...

Отзывы: