H0538700.

B

 - EN - 2015-09

3

1. Information before installing

1.1 General delivery terms and conditions

All equipment, even postage and packing paid, travels at the risks and perils of the recipient. Written reserves should be 

made on the transporter’s delivery documents if damage during transport is discovered by the recipient (confirmed by 

registered letter to the transporter within 48 hours).

1.2 Contents

FloPro™ e3

Ø63/50 mm union couplings

x1

x2

1.3 Technical specifications

• 

Power supplied: 1.0 HP - 750 W

• 

Mains power supply: 230 Vac - 50 Hz

• 

Operation from 1000 to 2850 rpm (set in ranges of 50 rpm)

•  Number of programmable speeds: 3

• 

Maximum rate at 8 metres from a water column: 18 m³/h

• 

Operating temperatures: from 2 to 50°C air and 2 to 35°C water

• 

Protection index: IPX5

2. Installation

2.1 Selecting the location

•  The pump must be installed: 

 

-

before the filter, a heating and/or water treatment system,

 

-

at a minimum distance of 3.5 metres from the edge of the pool, to avoid any water being sprayed onto the equipment. 

Some standards allow for other distances. Refer to the regulations in effect in the country of installation.

 

-

ideally 30 cm below the water level, 

 

-

out of an area subject to flooding, or on a base with drainage,

 

-

in a ventilated space to enable it to cool down.

•  The pump must not be installed: 

 

-

in an area subject to splashing or rain.

 

-

more than 1 m above the water level.

 

-

near a heat source or flammable gas.

• 

Fit a non-return valve if the filter is installed above the water level.

• 

Fit suction and discharge isolation valves if the pump is installed below the water level.

• 

Easy access is required for maintenance work on the equipment.

• 

Use as few elbow joints as possible.

2.2 Positioning the equipment

• 

Place on a stable, solid (e.g. concrete floor) and level surface.  

• 

If necessary, use the bases (2 types of base, not supplied, available as an option) to raise the pump to the level of the 

existing pipes. 

• 

 Screw the pump to the ground using the adapted foundation bolt. 

Содержание FloPro e3

Страница 1: ...H0538700 B 2015 09 Instructions for installation and use English More documents on www zodiac poolcare com EN TM...

Страница 2: ...possibly causing death It is important that this equipment is operated by competent and qualified both physically and mentally people who have previously received the instructions for use by reading...

Страница 3: ...Electric connections 4 3 Use 5 3 1 User interface presentation 5 3 2 Checks before starting up 5 3 3 Start the appliance 6 3 4 Use and configuration of the user interface 6 4 Maintenance 7 4 1 Mainten...

Страница 4: ...water treatment system ataminimumdistanceof3 5metresfromtheedgeofthepool toavoidanywaterbeingsprayedontotheequipment Some standards allow for other distances Refer to the regulations in effect in the...

Страница 5: ...rted to prevent any risk of breakage due to the weight of water 2 4 Electric connections Risk of electric shock inside the equipment may cause serious injury or even death Only a qualified and experie...

Страница 6: ...ing pump stopped powered up Fixed pump in operation LED The number of flashes indicates the error in progress 3 2 Checks before starting up Check that the hydraulic connections are correctly tightened...

Страница 7: ...ectrical compartment contain no foreign bodies Clean the outside of the appliance do not use solvent based products Check that the user interface is correctly connected Check the connection of the met...

Страница 8: ...ilter screen Air blocked in the circuit Swimming pool water level too low Incorrect pre filter cover seal Bleed the circuit Check the water level and top up if necessary Check that the cover and its s...

Страница 9: ...t on our website you will be the first to be informed of new Zodiac products and special offers You can help us to constantly improve our product quality Europe Rest of the World www zodiac poolcare c...

Страница 10: ...H0538700 B EN 2015 09 Dimensions Weight pump only 10 kg Description A Water admission B Water discharge C Pre filter cover D User interface E Pump motor F Drain Performance graphs Hydraulic head Flow...

Страница 11: ......

Страница 12: ...ase contact your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer www zodiac poolcare com Zodiac Pool Care Europe BP 90023 491...

Отзывы: