H0538700.
B
- EN - 2015-09
5
2.4.3 Connecting the motor's power supply
•
Open the electrical cabinet by unscrewing the 3 screws on the user interface and tilting it to the side (pay attention to
the wires underneath).
•
Run the supply cable through the gland and connect it to the
(earth) and L-N terminals:
•
Close the unit again, making sure that the seal is correctly in place.
•
Power supply cable section: provided for information purposes for a maximum length of 45 metres (calculation base:
NFC15-100), must be checked and adapted to the installation conditions and standards of the installation country.
•
Electrical characteristics:
Voltage
Maximum absorbed intensity
Cable cross-section
Electrical protection
A
mm²
Type
A
230V-50Hz
4.8
3x1.5
3G1.5
16
3. Use
3.1 User interface presentation
Symbol
Designation
Key
"ECO" speed activation
Speed reduction in setting mode
LED
Flashing: in priming mode (approx. 2 minutes on start-up)
Fixed: speed in operation
Key
"CLEAN" speed activation
Recording of the current setting (press for 10 seconds)
LED
Flashing: in priming mode (approx. 2 minutes on start-up)
Fixed: speed in operation
Key
"BOOST" speed activation
Speed increase in setting mode
LED
Flashing: in priming mode (approx. 2 minutes on start-up)
Fixed: speed in operation
Key
Shutdown of the speed during operation
LED
Flashing: pump stopped, powered up
Fixed: pump in operation
LED
The number of flashes indicates the error in progress
3.2 Checks before starting up
•
Check that the hydraulic connections are correctly tightened.
•
Check that the pump is stable, level and flush.
•
The electricity supply cable must be insulated against any cutting or hot elements that may damage it.
•
The hydraulic circuit must be bled and not contain any foreign bodies.
•
The pump pre-filter strainer cover must be correctly closed (by hand) and its seal clean and in place.
• Check that the valves are open.
•
To prevent against any risk of explosion that may cause material damage, serious injury or even death,
make sure that the hydraulic circuit is free of any debris or blockage and is not subject to excessive pressure.
•
Never run the pump "dry" as this may damage it.
•
The pre-filter strainer cover must be closed by hand (do not use any tools).
3.3 Start the appliance
•
Start a speed, the pump always starts in "priming" mode (2850 rpm for approx. 2 minutes).
•
The pump is self-priming. However, you are strongly recommended to fill the pre-filter strainer with water before
starting it up for the first time to facilitate the procedure.
•
Bleed any air present in the filtration circuit using the bleed normally present on the filter (refer to the swimming pool
filter's manual).
•
Check that there are no leaks on the hydraulic circuit.
The pump has a priming capacity up to 3 metres above the swimming pool water level (if the hydraulic circuit is
perfectly sealed).
Содержание FloPro e3