H0538700.

B

 - EN - 2015-09

4

2.3 Hydraulic connections

1: pump

2: filter

3: heating system

4: water treatment system

Respect the hydraulic connection direction (see $ "Dimensions" in the appendix).

Pipes

Maximum suction rate at 

1.8 metres/second

Maximum discharge rate at 

2.4 metres/second

Ø50 mm

14 m³/h

19 m³/h

Ø 63 mm

20 m³/h

27 m³/h

• 

Choose the dimension of the pipes according to the size of the pool and respecting the hydraulic rules which apply in 

the installation country.

•  Performance curves are available in the appendix for the pipe dimensions.

• 

The use of suction and discharge union couplings is recommended to facilitate operations on the equipment (the pump 

intake and output are threaded by 2" on the interior).

• 

If there need to be more than 10 elbow joints on the hydraulic circuit, increase the pipe diameter.

• 

Avoid high points to simplify priming. 

• 

Check that the hydraulic corrections are correctly tightened and that there are no leaks.

• 

The pipes must be supported to prevent any risk of breakage due to the weight of water.

2.4 Electric connections

• 

Risk of electric shock inside the equipment may cause serious injury or even death. Only a qualified and 

experienced technician is authorised to carry out cabling in the equipment. 

• 

The equipment must be connected to an earth socket.

• 

Any unsuitable electrical connection will invalidate the warranty.

• 

Incorrectly tightened terminals may cause the terminal unit to heat up and invalidate the warranty.

• 

If the supply cable is damaged, it must be replaced by a qualified technician.

2.4.1 Voltage and protection

• 

Electrical protection: by circuit breaker (D curve), with a 30 mA dedicated differential circuit breaker (circuit breaker or 

switch) at the head of the line.

• 

The equipment and the swimming pool and any other electrical equipment must be connected to the Earth.

Acceptable variation in voltage: +/-10% (during operation).

2.4.2 Power supply and clock

Connect the pump to the 230 Vac relay downstream of the swimming pool electrical cabinet's filtration clock.

The filtration unit clock directly controls the pump's electricity supply, which then starts with the selected speed.

Содержание FloPro e3

Страница 1: ...H0538700 B 2015 09 Instructions for installation and use English More documents on www zodiac poolcare com EN TM...

Страница 2: ...possibly causing death It is important that this equipment is operated by competent and qualified both physically and mentally people who have previously received the instructions for use by reading...

Страница 3: ...Electric connections 4 3 Use 5 3 1 User interface presentation 5 3 2 Checks before starting up 5 3 3 Start the appliance 6 3 4 Use and configuration of the user interface 6 4 Maintenance 7 4 1 Mainten...

Страница 4: ...water treatment system ataminimumdistanceof3 5metresfromtheedgeofthepool toavoidanywaterbeingsprayedontotheequipment Some standards allow for other distances Refer to the regulations in effect in the...

Страница 5: ...rted to prevent any risk of breakage due to the weight of water 2 4 Electric connections Risk of electric shock inside the equipment may cause serious injury or even death Only a qualified and experie...

Страница 6: ...ing pump stopped powered up Fixed pump in operation LED The number of flashes indicates the error in progress 3 2 Checks before starting up Check that the hydraulic connections are correctly tightened...

Страница 7: ...ectrical compartment contain no foreign bodies Clean the outside of the appliance do not use solvent based products Check that the user interface is correctly connected Check the connection of the met...

Страница 8: ...ilter screen Air blocked in the circuit Swimming pool water level too low Incorrect pre filter cover seal Bleed the circuit Check the water level and top up if necessary Check that the cover and its s...

Страница 9: ...t on our website you will be the first to be informed of new Zodiac products and special offers You can help us to constantly improve our product quality Europe Rest of the World www zodiac poolcare c...

Страница 10: ...H0538700 B EN 2015 09 Dimensions Weight pump only 10 kg Description A Water admission B Water discharge C Pre filter cover D User interface E Pump motor F Drain Performance graphs Hydraulic head Flow...

Страница 11: ......

Страница 12: ...ase contact your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer www zodiac poolcare com Zodiac Pool Care Europe BP 90023 491...

Отзывы: