manualshive.com logo in svg
background image

EN

H0538700.

B

 - EN - 2015-09

6

3.4 Use and configuration of the user interface

Speed

Keys to start the speed

Default speed

"ECO" speed

1400 rpm

"CLEAN" speed

2150 rpm

"BOOST" speed

2850 rpm

• 

When the pump is running, it displays the operating speed and an LED lights up above the key which corresponds to 

the speed.

If the mains supply is disconnected (manually or via the filtration clock) the pump will restart at the last speed 

active.

• 

To modify the setting of one of the three speeds:

 -

the speed you want to modify must be operating,

 -

press the key that corresponds to this speed for 5 seconds (the corresponding green LED must flash).

 - press  

 or 

 until you reach the speed you want (increments of 50 rpm).

 - Press  

 for 10 seconds to save. 

•  To stop the pump, press 

.

You may reset the pump to return it to "factory" configuration:

- make sure that the pump is powered up but stopped ("OFF" is displayed on the screen).

- press 

 + 

 +  

 for 5 seconds until the 3 corresponding green LEDs flash once.

- release the keys: the pump is now reset.

4. Maintenance

4.1 Maintenance instructions

General maintenance of the appliance is recommended when the pool is wintered and before restarting, to 

check that it operates correctly and maintains its performance, as well as to prevent certain types of failure.

These operations are carried out at the user's expense, by a qualified technician.

•  Make sure that the pump or electrical compartment contain no foreign bodies.

•  Clean the outside of the appliance, do not use solvent-based products.

• 

Check that the user interface is correctly connected.

• 

Check the connection of the metal masses to the earth.

• 

Check that the electrical cables are correctly tightened and connected and that the electrical unit is clean.

• 

Clean the pre-filter strainer, the cover and the seal regularly.

• 

Check that the pre-filter strainer is correctly in place, or it may prevent the cover from closing fully.

4.2 Wintering

The pump must be fully wintered in the event of frost or extended electrical disconnection. If the pump freezes 

it may cause severe damage and invalidate the warranty. 

To avoid damaging the equipment with condensation, do not fully cover it.

• 

If the pump is positioned below the water level, close the isolation valves at suction and 

discharge.

• 

Drain  the  pump  (using  the  2  bleed  screws)  and  the  hydraulic  circuit,  following  the  swimming  pool  manufacturer's 

instructions.

• 

Remove the 2 bleed screws and keep them to reinstall them when the pump is put back into operation.

• 

You are recommended to disconnect the electrical power cable then unscrew the hydraulic connectors to store the 

pump in a dry place away from frost.

4.3 Recycling

This symbol means that your appliance must not be thrown into a normal bin. It will be selectively collected for the 

purpose of reuse, recycling or creating value. If it contains any substances that may be harmful to the environment, 

these will be eliminated or neutralised.

Contact your dealer for recycling information.

Содержание FloPro e3

Страница 1: ...H0538700 B 2015 09 Instructions for installation and use English More documents on www zodiac poolcare com EN TM...

Страница 2: ...possibly causing death It is important that this equipment is operated by competent and qualified both physically and mentally people who have previously received the instructions for use by reading...

Страница 3: ...Electric connections 4 3 Use 5 3 1 User interface presentation 5 3 2 Checks before starting up 5 3 3 Start the appliance 6 3 4 Use and configuration of the user interface 6 4 Maintenance 7 4 1 Mainten...

Страница 4: ...water treatment system ataminimumdistanceof3 5metresfromtheedgeofthepool toavoidanywaterbeingsprayedontotheequipment Some standards allow for other distances Refer to the regulations in effect in the...

Страница 5: ...rted to prevent any risk of breakage due to the weight of water 2 4 Electric connections Risk of electric shock inside the equipment may cause serious injury or even death Only a qualified and experie...

Страница 6: ...ing pump stopped powered up Fixed pump in operation LED The number of flashes indicates the error in progress 3 2 Checks before starting up Check that the hydraulic connections are correctly tightened...

Страница 7: ...ectrical compartment contain no foreign bodies Clean the outside of the appliance do not use solvent based products Check that the user interface is correctly connected Check the connection of the met...

Страница 8: ...ilter screen Air blocked in the circuit Swimming pool water level too low Incorrect pre filter cover seal Bleed the circuit Check the water level and top up if necessary Check that the cover and its s...

Страница 9: ...t on our website you will be the first to be informed of new Zodiac products and special offers You can help us to constantly improve our product quality Europe Rest of the World www zodiac poolcare c...

Страница 10: ...H0538700 B EN 2015 09 Dimensions Weight pump only 10 kg Description A Water admission B Water discharge C Pre filter cover D User interface E Pump motor F Drain Performance graphs Hydraulic head Flow...

Страница 11: ......

Страница 12: ...ase contact your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer www zodiac poolcare com Zodiac Pool Care Europe BP 90023 491...

Отзывы: