5.6 

eStar Speed

The "

" speed is intended to be used as an 

energy-efficient setting that can be easily called-up by 
activating the eStar preset speed from the keypad or 
remote closure. After this speed has been determined 
by the installer, the eStar preset may be set as follows: 
From the service setup menu, select 

SET ESTAR 

SPEED

. Press 

MENU

. Using the arrow keys, set the 

speed to the desired value. Press 

MENU

 to accept and 

store.

5.7 

Pump Freeze Protect Operation

When enabled to do so, the ePump™ controller 

monitors the temperature inside the pump and will 
activate the ePump™ at the eStar speed when the 
temperature approaches freezing. The run duration of 
the pump freeze protect operation is adjustable from 30 
minutes to 8 hours, or may be disabled completely.

To set the pump freeze protect operation, 

from the service setup menu select 

PUMP FREEZE 

PROTECT

. Press 

MENU

. Using the arrow keys, set the 

duration to the desired value. To disable pump freeze 
protect, set the duration to 0:00. Press 

MENU

 to accept 

and store.

IMPORTANT INFORMATION  

ON FREEZE PROTECTION

Freeze protection is intended to protect equipment and 
plumbing for short periods of freezing only. It does this 
by activating the filtration pump and circulating the water 
to prevent freeze inside equipment or plumbing. Freeze 
protection does not guarantee that equipment will not be 
damaged by extended periods of freezing temperatures 
or power outages. In these conditions, the pool and spa 
should be shut down completely (e.g. drained of water and 
closed for the winter) until warmer weather exists.

The pump freeze protect run time may be 

interrupted by pressing a preset key, as follows:

Pressing the key "

" once overrides the pump 

freeze protect run time, pressing it twice turns off the 
pump. Pressing other preset keys will override the pump 
freeze protect run time and activate the selected preset 
speed.

Section 6. User Set Up Operation

NOTE

  The controller must be in the 

OFF

 mode before 

entering the Setup Mode is possible. While in 
Setup Mode the controller will return back to the 

OFF

 mode after one minute since the last key 

press.

In general, when in setup mode, preset keys 

"

" through "4" are used as ‘escape’ or exit keys while 

navigating the setup menu.

To enter the setup mode, press and hold the 

MENU

 button for five (5) seconds. The controller 

displays 

SELECT USER SETUP. 

Using the arrow keys, 

select the desired setup item to change.

Содержание ePump

Страница 1: ...t must be installed and serviced by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in p...

Страница 2: ......

Страница 3: ...r 9 3 1 The ePump Controller 9 3 2 The ePump Controller Interface 9 3 3 Basic Functions 10 Section 4 User Operation 10 4 1 OFF Mode 10 4 2 RUN Mode 10 4 3 Manual Start and Stop 10 4 4 Pump Speed Setti...

Страница 4: ...en or missing Never replace a suction fitting with one rated less than the flow rate marked on the equipment assembly WARNING To Reduce the Risk of Injury a The water in a spa should never exceed 40 C...

Страница 5: ...mometer Do not use a spa or hot tub immediately following strenuous exercise Prolonged immersion in a spa or hot tub may be injurious to your health Do not permit any electric appliance such as a ligh...

Страница 6: ...r Components The ePump controller assembly See Figure 2 contains the following components 1 ePump Controller 2 Mounting Gasket 3 Backplate 4 Round Seal 5 Six 6 Screws Additional materials are required...

Страница 7: ...igure 2 5 Mark the hole locations on the wall and use the fastener to secure the backplate to the wall 6 At the bottom of the backplate cut the two 2 tabs out with an appropriate tool such as a Stanle...

Страница 8: ...n on all switches and the main breaker feeding power to the ePump 5 Verify the operation of the contact closures If the correct speed is activated when the closure is activated the ePump starts and th...

Страница 9: ...in breaker feeding power to the ePump 8 If the installation is working properly the fireman s switch will open 20 minutes before the booster pump shuts down the ePump will continue to run for 30 minut...

Страница 10: ...time of day clock 4 2 RUN Mode When the pump is running not off the controller displays n label 00 00 RPM xxxx where n label is the number and label of the selected preset 00 00 is the time of day clo...

Страница 11: ...e only within a certain range The minimum and maximum limits of the range are set by the installer 4 5 Timeclock Setup and Operation The controller allows the user to create timed pump programs on pum...

Страница 12: ...hen starting the pump via a timed program the pump will first run at the priming speed for the priming duration as set by the installer If a program overlap occurs the pump will immediately start at t...

Страница 13: ...ller for further information 4 7 Pump Freeze Protect To help protect against pump damage the controller monitors the temperature inside the pump If enabled pump freeze protect will start the pump at t...

Страница 14: ...Minimum and maximum pump speeds eStar speed Pump Freeze Protect operation 5 1 Entering Service Setup NOTE The ePump controller must be in the OFF mode all LED s lights must be off before entering the...

Страница 15: ...To clear the fault history press either arrow key 5 5 Priming Speed and Duration The ePump controller will command the ePump to operate at the priming speed for the priming duration specified except d...

Страница 16: ...protect equipment and plumbing for short periods of freezing only It does this by activating the filtration pump and circulating the water to prevent freeze inside equipment or plumbing Freeze protec...

Страница 17: ...SET Press the MENU button to display the currently selected preset Using the arrow keys choose the preset to be changed Press MENU to select The controller displays SELECT LABEL TYPE Select GENERAL or...

Страница 18: ...election From the setup menu select LANGUAGE using the arrow keys Press MENU Using the arrow keys select the desired language Press MENU to save the selection 6 7 Run Duration Presets 3 and 4 Only Pre...