Page 16
5.6
eStar Speed
The "
" speed is intended to be used as an
energy-efficient setting that can be easily called-up by
activating the eStar preset speed from the keypad or
remote closure. After this speed has been determined
by the installer, the eStar preset may be set as follows:
From the service setup menu, select
SET ESTAR
SPEED
. Press
MENU
. Using the arrow keys, set the
speed to the desired value. Press
MENU
to accept and
store.
5.7
Pump Freeze Protect Operation
When enabled to do so, the ePump™ controller
monitors the temperature inside the pump and will
activate the ePump™ at the eStar speed when the
temperature approaches freezing. The run duration of
the pump freeze protect operation is adjustable from 30
minutes to 8 hours, or may be disabled completely.
To set the pump freeze protect operation,
from the service setup menu select
PUMP FREEZE
PROTECT
. Press
MENU
. Using the arrow keys, set the
duration to the desired value. To disable pump freeze
protect, set the duration to 0:00. Press
MENU
to accept
and store.
IMPORTANT INFORMATION
ON FREEZE PROTECTION
Freeze protection is intended to protect equipment and
plumbing for short periods of freezing only. It does this
by activating the filtration pump and circulating the water
to prevent freeze inside equipment or plumbing. Freeze
protection does not guarantee that equipment will not be
damaged by extended periods of freezing temperatures
or power outages. In these conditions, the pool and spa
should be shut down completely (e.g. drained of water and
closed for the winter) until warmer weather exists.
The pump freeze protect run time may be
interrupted by pressing a preset key, as follows:
Pressing the key "
" once overrides the pump
freeze protect run time, pressing it twice turns off the
pump. Pressing other preset keys will override the pump
freeze protect run time and activate the selected preset
speed.
Section 6. User Set Up Operation
NOTE
The controller must be in the
OFF
mode before
entering the Setup Mode is possible. While in
Setup Mode the controller will return back to the
OFF
mode after one minute since the last key
press.
In general, when in setup mode, preset keys
"
" through "4" are used as ‘escape’ or exit keys while
navigating the setup menu.
To enter the setup mode, press and hold the
MENU
button for five (5) seconds. The controller
displays
SELECT USER SETUP.
Using the arrow keys,
select the desired setup item to change.