background image

Page 14

To set the maximum speed, from the service 

setup menu, select 

SET MAx LIMIT

 using the arrow 

keys. Press 

MENU

. Using the arrow keys, set the 

maximum speed to the desired value. Press 

MENU

 to 

accept and store.

5.3 

Load Defaults

To restore factory default settings to the 

controller, from the service setup menu, select 

LOAD 

DEFAULTS

. Press 

MENU

. Using the arrow keys, select 

YES

. Press 

MENU

 to restore factory default settings.

Section 5. Service Setup Options

The service setup menu allows the installer to 

set various operating parameters, view fault history, and 
restore factory defaults.

Parameters that may be modified and set in the 

service setup menu include:

 

• Priming speed and duration.

 

• Minimum and maximum pump speeds.

 

• "

" eStar speed.

 

• Pump Freeze Protect operation.

5.1 

Entering Service Setup

NOTE

  The ePump™ controller must be in the OFF 

mode (all LED's lights must be off) before 
entering the user setup mode. While in setup 
mode the controller will return back to the OFF 
mode after one (1) minute since the last key 
press.

To enter the service setup menu, press and hold 

MENU

, then press and hold the "

" and preset "4" 

keys. Hold all three (3) keys down for five (5) seconds. 
To exit, press any preset button.

5.2 

Minimum and Maximum Pump 
Speeds

These speeds are considered global settings 

across the entire controller, and create the range of 
allowable speed that may be sent to the ePump™.

To set the minimum speed, from the service 

setup menu, select 

SET MIN LIMIT

 using the arrow 

keys. Press 

MENU

. Using the arrow keys, set the 

minimum speed to the desired value. Press 

MENU

 to 

accept and store.

Содержание ePump

Страница 1: ...t must be installed and serviced by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in p...

Страница 2: ......

Страница 3: ...r 9 3 1 The ePump Controller 9 3 2 The ePump Controller Interface 9 3 3 Basic Functions 10 Section 4 User Operation 10 4 1 OFF Mode 10 4 2 RUN Mode 10 4 3 Manual Start and Stop 10 4 4 Pump Speed Setti...

Страница 4: ...en or missing Never replace a suction fitting with one rated less than the flow rate marked on the equipment assembly WARNING To Reduce the Risk of Injury a The water in a spa should never exceed 40 C...

Страница 5: ...mometer Do not use a spa or hot tub immediately following strenuous exercise Prolonged immersion in a spa or hot tub may be injurious to your health Do not permit any electric appliance such as a ligh...

Страница 6: ...r Components The ePump controller assembly See Figure 2 contains the following components 1 ePump Controller 2 Mounting Gasket 3 Backplate 4 Round Seal 5 Six 6 Screws Additional materials are required...

Страница 7: ...igure 2 5 Mark the hole locations on the wall and use the fastener to secure the backplate to the wall 6 At the bottom of the backplate cut the two 2 tabs out with an appropriate tool such as a Stanle...

Страница 8: ...n on all switches and the main breaker feeding power to the ePump 5 Verify the operation of the contact closures If the correct speed is activated when the closure is activated the ePump starts and th...

Страница 9: ...in breaker feeding power to the ePump 8 If the installation is working properly the fireman s switch will open 20 minutes before the booster pump shuts down the ePump will continue to run for 30 minut...

Страница 10: ...time of day clock 4 2 RUN Mode When the pump is running not off the controller displays n label 00 00 RPM xxxx where n label is the number and label of the selected preset 00 00 is the time of day clo...

Страница 11: ...e only within a certain range The minimum and maximum limits of the range are set by the installer 4 5 Timeclock Setup and Operation The controller allows the user to create timed pump programs on pum...

Страница 12: ...hen starting the pump via a timed program the pump will first run at the priming speed for the priming duration as set by the installer If a program overlap occurs the pump will immediately start at t...

Страница 13: ...ller for further information 4 7 Pump Freeze Protect To help protect against pump damage the controller monitors the temperature inside the pump If enabled pump freeze protect will start the pump at t...

Страница 14: ...Minimum and maximum pump speeds eStar speed Pump Freeze Protect operation 5 1 Entering Service Setup NOTE The ePump controller must be in the OFF mode all LED s lights must be off before entering the...

Страница 15: ...To clear the fault history press either arrow key 5 5 Priming Speed and Duration The ePump controller will command the ePump to operate at the priming speed for the priming duration specified except d...

Страница 16: ...protect equipment and plumbing for short periods of freezing only It does this by activating the filtration pump and circulating the water to prevent freeze inside equipment or plumbing Freeze protec...

Страница 17: ...SET Press the MENU button to display the currently selected preset Using the arrow keys choose the preset to be changed Press MENU to select The controller displays SELECT LABEL TYPE Select GENERAL or...

Страница 18: ...election From the setup menu select LANGUAGE using the arrow keys Press MENU Using the arrow keys select the desired language Press MENU to save the selection 6 7 Run Duration Presets 3 and 4 Only Pre...

Страница 19: ...Page 19 Section 7 Menu Flow Chart...

Страница 20: ...H0352000 Zodiac Group Australia Pty Ltd 219 Woodpark Road Smithfield NSW 2164 Ph 1800 688 552 Fax 02 9756 3987...

Отзывы: