background image

Page 18

6.5 

Display Light Control

The controller’s display is equipped with a 

backlight to aid viewing in low light conditions.

From the setup menu, select 

DISPLAY LIGHT

Press 

MENU

. Using the arrow keys, select the desired 

operating mode for the display backlight:

LIGHT OFF - 

Turn off display backlight.

LIGHT ON - 

Turn on display backlight.

2 MIN TIMEOUT - 

Turn on display backlight, 

with automatic turn-off after two (2) minutes since the 
last key press.

6.6 

Language Selection

From the setup menu, select 

LANGUAGE

 using 

the arrow keys. Press 

MENU

. Using the arrow keys, 

select the desired language. Press 

MENU

 to save the 

selection.

6.7 

Run Duration (Presets 3 and 4 Only)

Presets "3" and "4" may be programmed to run 

for a specified duration after being manually started. 
This run duration is programmable from 30 minutes to 
8 hours, in increments of 30 minutes. A setting of 0:00 
disables the run duration feature, allowing the preset to 
run indefinitely.

From the setup menu, select 

RUN DURATION

Press 

MENU

. Select the preset to be programmed. Press 

MENU

. Set the desired run duration for the preset using 

the arrow keys. Press 

MENU

 to accept.

Содержание ePump

Страница 1: ...t must be installed and serviced by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in p...

Страница 2: ......

Страница 3: ...r 9 3 1 The ePump Controller 9 3 2 The ePump Controller Interface 9 3 3 Basic Functions 10 Section 4 User Operation 10 4 1 OFF Mode 10 4 2 RUN Mode 10 4 3 Manual Start and Stop 10 4 4 Pump Speed Setti...

Страница 4: ...en or missing Never replace a suction fitting with one rated less than the flow rate marked on the equipment assembly WARNING To Reduce the Risk of Injury a The water in a spa should never exceed 40 C...

Страница 5: ...mometer Do not use a spa or hot tub immediately following strenuous exercise Prolonged immersion in a spa or hot tub may be injurious to your health Do not permit any electric appliance such as a ligh...

Страница 6: ...r Components The ePump controller assembly See Figure 2 contains the following components 1 ePump Controller 2 Mounting Gasket 3 Backplate 4 Round Seal 5 Six 6 Screws Additional materials are required...

Страница 7: ...igure 2 5 Mark the hole locations on the wall and use the fastener to secure the backplate to the wall 6 At the bottom of the backplate cut the two 2 tabs out with an appropriate tool such as a Stanle...

Страница 8: ...n on all switches and the main breaker feeding power to the ePump 5 Verify the operation of the contact closures If the correct speed is activated when the closure is activated the ePump starts and th...

Страница 9: ...in breaker feeding power to the ePump 8 If the installation is working properly the fireman s switch will open 20 minutes before the booster pump shuts down the ePump will continue to run for 30 minut...

Страница 10: ...time of day clock 4 2 RUN Mode When the pump is running not off the controller displays n label 00 00 RPM xxxx where n label is the number and label of the selected preset 00 00 is the time of day clo...

Страница 11: ...e only within a certain range The minimum and maximum limits of the range are set by the installer 4 5 Timeclock Setup and Operation The controller allows the user to create timed pump programs on pum...

Страница 12: ...hen starting the pump via a timed program the pump will first run at the priming speed for the priming duration as set by the installer If a program overlap occurs the pump will immediately start at t...

Страница 13: ...ller for further information 4 7 Pump Freeze Protect To help protect against pump damage the controller monitors the temperature inside the pump If enabled pump freeze protect will start the pump at t...

Страница 14: ...Minimum and maximum pump speeds eStar speed Pump Freeze Protect operation 5 1 Entering Service Setup NOTE The ePump controller must be in the OFF mode all LED s lights must be off before entering the...

Страница 15: ...To clear the fault history press either arrow key 5 5 Priming Speed and Duration The ePump controller will command the ePump to operate at the priming speed for the priming duration specified except d...

Страница 16: ...protect equipment and plumbing for short periods of freezing only It does this by activating the filtration pump and circulating the water to prevent freeze inside equipment or plumbing Freeze protec...

Страница 17: ...SET Press the MENU button to display the currently selected preset Using the arrow keys choose the preset to be changed Press MENU to select The controller displays SELECT LABEL TYPE Select GENERAL or...

Страница 18: ...election From the setup menu select LANGUAGE using the arrow keys Press MENU Using the arrow keys select the desired language Press MENU to save the selection 6 7 Run Duration Presets 3 and 4 Only Pre...

Страница 19: ...Page 19 Section 7 Menu Flow Chart...

Страница 20: ...H0352000 Zodiac Group Australia Pty Ltd 219 Woodpark Road Smithfield NSW 2164 Ph 1800 688 552 Fax 02 9756 3987...

Отзывы: