ZMC408CE Motion Controller Hardware Manual V1.5
close
Overcurrent
protection
Support
Support
Isolation method
optoelectronic isolation
Note:
The times in the form are typical based on the resistive load, and may change
when the load circuit changes.
Due to the leak-type output, the shutdown of the output will be obviously
affected by the external load circuit, and the output frequency should not be set
too high in the application. For high-speed output, it is recommended to set
below 400KHz, for low-speed output, it is recommended to set below 8KHz. For
more higher speed, please contact us to adjust parameters or custom hardware.
→
Wiring Reference
→
Wiring Note:
⚫
The wiring principle of high-speed digital output OUT (0-7) and low-speed digital
output OUT (8-15) is shown in the figure above. The external signal receiving end can
be an optocoupler or a relay or solenoid valve, all can be connected as long as the
input current does not exceed 300mA.
⚫
For the connection of the public end, please connect the "EGND" port on the power
supply to the negative pole of the DC power supply of the external input device. If the
DC power supply of the external device and the controller power supply are in the
Содержание ZMC408CE
Страница 1: ......