If you select a port that does not exist, the message “Unable to open port” will appear.
If you open the wrong port the port will open but you will not get any open message.
In either of the above 2 cases, simply make your selection again.
The default parameters.
By default, the parameters that are set are as follows;
Mode = 5 bit baudot.
Baudrate = 45.45 (Same as 45).
Polarity = Normal.
UnShiftOnSpace = ON.
StopBits = 1.5.
If you wish to operate with different settings you can select the parameters from the menu bar.
All standard baudrates can be selected from the top menu bar. Should you wish to enter your own
non-standard baudrate simply enter the baudrate into the lower “USR” window and click the “USR”
button. The interface will calculate the timings for ANY baudrate between 10 – 600 baud.
Содержание DigiMaster Pro3
Страница 4: ......
Страница 11: ...In FLWKey Select Configure then select the port to which the Keyer is attached ...
Страница 13: ...In WinTest ...
Страница 15: ...The following window will open Double click the USB audio CODEC which will open another window ...
Страница 18: ......