35
and
trigger Door open and Alarm
.
Verify Mode by RS485
:
To turn on RS485 reader function; it is the verification method used by the
device when it is the master/slave device.
Speaker Alarm:
When the
[Speaker Alarm]
is enabled, the speaker will raise an alarm when the device
is being dismantled.
Reset Access Setting:
To reset parameters of door lock delay, door sensor delay, door sensor type,
verification mode, door available time period, NO time period, auxiliary input configuration, speaker alarm,
anti-passback direction,. However, the content of the Access Data deletion in
[Data Mgt.]
will not be
affected.
Access Parameters
Factory Default
Door Lock Delay
5 s
Door Sensor Delay
10 s
Door Sensor Type
Normal Open (NO)
Verification Mode
Password/Fingerprint/Badge
Door Available Time Period 1
NO Time Period
None
Aux output/Lock open time 255 s
Aux output type setting
Trigger door open
Speaker Alarm
Off
Anti-Passback Direction
No anti-passback
10.2 Time Rule Settings
Time Rule
is the minimum time unit of access control settings; at most 50
Time Rules
can be set for the
system. Each
Time Rule
consists of 7 time schedules (a week) and 3 holiday time schedules, and each
time schedule is the valid time within 24 hrs.
You may set a maximum of 3 time periods for every time schedule. The relationship among these time
periods is "or". When the verification time falls in any one of these time periods, the verification is valid.
The time period format is HH:MM-HH:MM in the 24-hour system with precision to minute.