other one is installed outside the door (slave device). The two devices communicate via Wiegand signal.
The Wiegand format and Output type (User ID / Badge Number) adopted by the master device and slave
device must be consistent.
In the initial interface, press >
Access Control
>
Anti-passback Setup
to enter the
Anti-passback
Setup
interface. Select Anti-passback Direction.
Anti-Passback Direction
No Anti-passback:
Anti-Passback function is disabled, which means passing verification of either master
device or slave device can unlock the door. Access records are not reserved.
Out Anti-passback:
After a user checks out, only if the last record is a check-in record can the user check
out again; otherwise, the alarm will be triggered. However, the user can check in freely.
In Anti-passback:
After a user checks in, only if the last record is a check-out record can the user check in
again; otherwise, the alarm will be triggered. However, the user can check out freely.
In/Out Anti-passsback:
After a user checks in/out, only if the last record is a check-out record can the
user check in again, or a check-in record can the user check out again; otherwise, the alarm will be
triggered.
Out
Master Device
Slave Device
User
Door
In