24 ProCapture-T & PRoRF-T User Manual
1:1 Retry Times:
In 1:1 Verification or Password Verification, users might forget the registered fingerprint
or password, or press the finger improperly. To reduce the process of re-entering user ID, retry is allowed;
the number of retry can be within 1~9.
Fingerprint Image:
To set whether to display the fingerprint image on the screen in registration or
verification. Four choices are available: Show for enroll, Show for match, Always show, None.
7.3 Reset to Factory Settings
Reset data such as communication settings and system settings to factory settings.
In the initial interface, press >
System
>
Reset
>
OK
to finish the reset
setting.
Reset parameters include Access Control Options, Anti-passback Setup, communication setting (namely,
the setting of Ethernet, Serial Comm., PC Connection and Wiegand Setup), Personalize (such as Voice
Prompt, Keyboard Prompt, Volume and Idle Time To Sleep) etc.
Parameters
Factory Defaults
Access Control Options
Door Lock Delay: 5 seconds
Door Sensor Delay: 10 seconds
Door Sensor Type: Normal Open (NO)
Verification Mode: Password / Fingerprint / Badge
Door available time period: 1
NO Time Period : None
Use as master: In
Aux output / Lock open time: 255 seconds
Aux output type setting: trigger door open
Speaker Alarm: OFF
Anti-passback Direction
No Anti-passback