Error! Use the Home tab to apply
标题
1 to the text that you want to appear here.
17
6.5 Wiegand Setup
In the initial interface, press
>
Comm.
>
Wiegand Setup
to enter the
Wiegand Setup
setting
interface.
6.5.1 Wiegand Input
Wiegand Input connector supports card reader, or connects the device as a master device to another
device (slave device), forming a master/slave system.
Select “Wiegadn Input” and
press to enter
Set parameters in “Wiegand Input” interface
Wiegand Format:
User can choose among the following built-in Wiegand formats: Wiegand 26,
Wiegand 26a, Wiegand 34, Wiegand 34a, Wiegand 36, Wiegand 36a, Wiegand 37, Wiegand 37a and
Wiegand 50.
Pulse Width (us):
The width of pulse sent by Wiegand card reader. The default value is 100 microseconds,
which can be adjusted within the range of 20 to 100 microseconds.
Pulse Interval (us):
The default value is 1000 microseconds, which can be adjusted within the range of 200
to 20000 microseconds.
ID Type:
Input content included in Wiegand input signal.
User ID
or
Badge Number
can be chosen.
Definitions of Wiegand Formats:
Wiegand Format
Definition