MA300 User Manual
ZKTechnology EU
29
among the three zones. It is effective if only one is satisfied.
2. Access Holiday Setting:
Special access control time may need during holiday. It is different to
modify everybody’s access control time. So a holiday access control time
can be set, which is applicable for all employees.
3. Access Group Time Zone:
Grouping is to manage employees in groups. Employee in groups use
group time zone by default. Group members can also set user time zone.
Every group can hold there time zones. The new enrolled user belongs to
Group 1 by default and can also be allocated to other groups.
4. Unlock Combination Setting:
Make various groups into different access controls to achieve
multi-verification and improve security. An access control can be made up
of 5 groups at most.
5. Access Control Parameters:
Lock Control Delay:
Apply to determine unlock hour, the min measured
unit is20ms, in the normal condition is 100-200ms.
Anti-Pass Mode:
Can be set to "None", "Out ", “In”, “InOut”.
Master’s record state
: Can be set to “None”, “Out”, “In”.
Sensor Mode
: Set Door Sensor Mode. It can be set to “None”, “NOpen”,
“NClose” state.
Sensor Delay
: Set the sensor delay time when the door is opened. After
this defined time the sensor detect the door state. If the door state is not
consistent the alarm will be triggered. Black and white screen device
range is 0-254. Color screen device range is 0-99.
Sensor Alarm
: Set the alarm time delay after the alarm is triggered.
Range is 0-999 seconds.
Error times to alarm:
Define the max error times to trigger alarm. When
the verify is not through, and exceed this defined times, the alarm signal
Содержание MA300