User Manual V1.1
38
out, in, or out-in anti-pass back.
When master machine is set as “out anti-pass back”, if user wants to
come in and go out normally, his recent record must be “in”, or he cannot
go out. Any “out” record will be “anti-pass back refused”. For example, a
user’s recent record is “in”, his second record can be “out” or “in”. His
third record is based on his second record. Out record and in record must
match (
Notice:
If customer has no any record before, then he can come
in but cannot go out).
When the master machine is set as “in anti-pass back”, if the user wants
to come in and go out normally, his recent record must be “out”, or he
cannot go out. Any out record will be “anti-pass back refused” by the
system (Notice: If the customer has no former record, then he can go out,
but cannot come in).
When the master machine is set as “out-in anti-pass back”, if the user
wants to come in and go out normally, if his recent record is “out” and “in”,
then his next record must be “ in” and “out”.
【
operation
】
1. Select model
Master machine: Machine with Wiegand in function, except for F10
reader.
Slave machine: Machine with Wiegand Out function.
2. Set anti-pass back direction and device status.
3. Modify device’s Wiegand output format
When the two devices are communicating, only Wiegand signals without
device ID are received.
4. Enroll user
The user must be on master machine and slave machine at the same
time, and user PIN must be the same. Therefore, it is necessary to enroll
user on master machine and slave machine at the same time.