5
808081 v1.01 06.21 Industrial Tap Instructions
• Use the template supplied on pages 6-7
to locate and cut the 35mm hole and 3x
6.5mm clearance holes in the correct
orientation for either left or right hand
operation.
• Use 3x cap screws to suit your benchtop
thickness.
• Apply a light smearing of silicone sealant
on the underside of the O-ring seal to
ensure a watertight fit.
• Pass the tubes and USB cable through
the Ø35mm hole.
• From below the bench, feed the three
tubes and USB cable through the clamp
block, noting the orientation marker.
• Fit the 3 cap screws and spring washers.
Tighten with an allen key.
• Use a tube spanner to secure the fixing
nut.
2
Side Touch Tap installation
Installation: Side Touch Tap (sink)
Internal nuts
Tapered base
O-ring seal
Benchtop
Clamp block
Spring washer
Fixing nut
Cap screw
Benchtop
thickness
M6 x 35 (supplied)
14 - 18 mm
M6 x 30 (not supplied)
8 - 13 mm
M6 x 40 (not supplied)
19 - 24 mm