14
808081 v1.01 06.21 Industrial Tap Instructions
Tap Operation: Top Touch Tap
Filter Change
Light off:
filter is operating within
its normal specified lifespan.
Flashing slowly:
filter is due for
replacement. The LCD will show
“Filter Change”. Refer to the
User Guide to replace the filter
cartridge.
Red Boiling Water Light
On:
Boiling water is ready.
Flashing slowly: Water is below
the desired temperature.
Safety light
Light on:
No boiling water
will be dispensed unless the
RED and SAFETY buttons are
pressed simultaneously.
Controls
Lights
Boiling water
Press the RED and SAFETY buttons simul-
taneously, to dispense boiling water
for 5 - 15 seconds (adjustable). Release
the buttons to stop the flow of water.
Note:
No Boiling water will be
dispensed when Hot Isolation is
enabled.
Chilled water
Press the BLUE button to
dispense chilled for 5 - 15
seconds (adjustable).
Release the button to stop
the flow of water.
Blue Chilled Water Light
On:
chilled water temperature is
within the set range.
Flashing slowly:
chilled water
temperature is not within the set
range. During heavy usage, the
temperature can rise out of this
range.