3
808081 v1.01 06.21 Industrial Tap Instructions
Position the tap such that it dispenses into
the sink bowl with clearance for a cup or tea
pot.
Alternatively, refer to pages 8-9 for tap
installation on a Font.
Position Command Centre and Tap as close
together as possible.
BC Compact
Ensure that taps are positioned to minimise
the risks of scalding when dispensing
boiling water.
!
Tools needed for tap installation
In addition to normal tools, the following (or equivalent) will be required.
•
35mm diameter sheet metal hole punch for sinks.
•
35mm diameter hole saw for worktops.
•
Hole saw for font installation (optional - refer to font kit)
•
Tube spanner for fixing the tap assembly (supplied).
Water supply pressure requirements
Positioning
Min - Max pressure, kPA (bar)
HydroTap
170 (1.7) - 700 (7.0)
Booster
200 (2.0) - 700 (7.0)
Be aware of the risks of hazards which could
cause harm when using tools. Assess the
risks before starting the installation.
!
Before Installation