Zip HydroTap All-In-One 89944 Скачать руководство пользователя страница 5

HydroTap Installation and Operating Instructions  

                              Page 5 of 20

In addition to normal tools, the following will be required:

•  50mm diameter sheet metal hole punch for sink tops. (not supplied)

•  50mm diameter hole saw for timber bench tops. (not supplied)

•  Nut runner tube spanner (supplied) for fixing tap assembly.

 Special tools required

Step A - Installing the (Boiling / Chilled) HydroTap outlet

 

(see 

P10-13)

1.   Make sure that the tap location will allow the nozzle outlet, as well as the 

vent outlet, to drain into the sink. (see outlet details P10)

2.   Cut a 50mm hole in the bench / sink top.

3.   Ensure the silicon O-Ring remains in place as this is the moisture       

     

seal against the bench / sink top.  

A light smearing of silicon sealant    

on the O-Ring will ensure a watertight fit.

4.   Pass all hoses through the 50mm hole and carefully locate the Head 

Assembly on the bench / sink top.

5.   From the underside of the bench / sink, mount the ‘base block’ by feeding 

each of the tubes and electrical cable evenly in between the legs of the 
‘base block spider’. Slide it up to meet the ‘all thread rod’, and pass the 
‘all thread rod’ through the centre of the ‘base block’.

6.   Hold the ‘all thread’ steady and fit the 6mm ‘fixing nut’ to the ‘all thread’ 

using the tube spanner supplied in the kit. Check the Tap Head position 
before securing it tightly against the bench / sink top. 

NOTE 1: The tap assembly must not be positioned more than 900mm  

 

above the HydroTap unit.                                                                             
Failure to do this may result in poor water delivery.

NOTE 2: Under no circumstances should the Tap be twisted after the           

installation is complete.

 Installation  procedure

•  Power supply 220-240 Volt AC, for connection to the heater via a 10 amp (160/125) or 15 amp (240/175) GPO.

•  This switch must provide all-pole disconnection and a contact separation of at least 3mm installed in accordance 

with wiring rules.

•  Cold water supply with a minimum working pressure of 200 kPa and a maximum working pressure of 700 kPa 

connected via an isolation valve. If pressure is likely to exceed 700 kPa, install a 500 kPa Pressure Limiting Valve.

•  The fitting of an air flow vent cut into the top half of the cupboard door  concealing the HydroTap requiring a cut size 

of approximately 100mm circular, to provide adequate warm air displacement. In installations where high volume  
draw-off will occur, the fitting of the accessory exhaust fan is essential.

Important:  Do not proceed with the installation if these requirements are not met. 

CAUTION:

 In order to avoid a hazard due to the inadvertent resetting of the thermal cut out, this appliance must not be 

supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on 
and off by the utility

Installation Requirements 

continued

O - Ring seal

Base Block

Fixing nut

Tap

All-thread rod

Содержание HydroTap All-In-One 89944

Страница 1: ...e 1 of 20 Zip HydroTap All In One Filtered Boiling and Chilled water plus Hot and Cold water for kitchens and tea rooms Installation and Operating Instructions This Installation Instruction covers the...

Страница 2: ...on 20 Hydrotap All In One series are able to supply Boiling and Chilled water as well as Hot and Cold water all from the same tap The A series have their Boiling Chilled Hot and Cold outlets connected...

Страница 3: ...ded The system will operate satisfactorily only if the recommended air gaps are provided these are 65mm min rear clearance and 50mm side clearance An air vent is provided with each unit for high usage...

Страница 4: ...ollow the instructions on page 15 16 or contact your Service Provider Frost Protection If this appliance is located where the ambient air temperature could fall below 5 C when the heater is not in use...

Страница 5: ...t tightly against the bench sink top NOTE 1 The tap assembly must not be positioned more than 900mm above the HydroTap unit Failure to do this may result in poor water delivery NOTE 2 Under no circums...

Страница 6: ...y to tighten the hose firmly by hand Excess force may damage the O rings Check these joints for leaks during initial operation Measure and trim the blue silicon tube and connect it to the chilled wate...

Страница 7: ...Orient the USB plug carefully and connect do not force the plug Once connected fix the cable to the wall ensure it is away from any possible water splashes and is off the floor Fasten the tap body to...

Страница 8: ...it at that temperature for a short stabilization period Once stabilized the element will cycle ON bring the water to boiling point and hold it there for a short period The unit now carries out a self...

Страница 9: ...ing the handle up will decrease the flow rate and lowering the handle will increase the flow rate Lift the handle all the way up to turn the tap off When the handle is moved to the left the temperatur...

Страница 10: ...TO TAP 240V GPO NOTE IF THE FLOW RATE IS TOO FAST CUT THE RED SILICONE TUBE 75mm MINIMUM FROM THE BOTTOM OF THE BASE OF THE ALL IN ONE TAP INSERT THE TEFLON RESTRICTOR ABOUT 20mm INTO THE UPPER SEGME...

Страница 11: ...65 220 BENCHTOP CABINET DOOR 4mm BUFFER PAD TO ENSURE VENTILATION GAP BRAIDED HOSE BH1 FROM MAINS SUPPLY BRAIDED HOSE BH2 FROM DOMESTIC HOT WATER SUPPLY SILICONE HOSE FROM BOILING WATER TANK IN HYDRO...

Страница 12: ...ROM STEAM VENT IN HYDROTAP TO TAP SILICONE HOSE FROM CHILLED WATER TANK IN HYDROTAP UNIT TO TAP BH1 B H 2 B H 3 NOTE IF THE FLOW RATE IS TOO FAST CUT THE RED SILICONE TUBE 75mm MINIMUM FROM THE BOTTOM...

Страница 13: ...ALL IN ONE TAP VENTED VERSION MAINS AMBIENT WATER SUPPLY ISOLATION VALVE NOT SUPPLIED 220 65...

Страница 14: ...ing slowly The light will flash slowly when the filter is due for replacement and the LCD will show Filter Change Refer to Replacing the filter section of this document Boiling Water Lever Depressing...

Страница 15: ...ent cartridge and write today s date where shown on the label 8 Avoid touching the filter O rings and filter opening as this may cause bacterial contamination of the cartridge 9 Align cartridge tabs w...

Страница 16: ...o reset the Filter Change display after a filter has reached the end of its life refer to Replace Filter Instructions section of this document Press either Mode or Mode button until Litres Filtered is...

Страница 17: ...vice mode To access the service mode Press both the Adjust and Adjust buttons simultaneously and hold for several seconds until the screen displays the HOT and COLD temperatures Press the Mode button...

Страница 18: ...k 3 three times rapidly the LED s will scroll from left to right 3 three times This operation confirms the activation 4 This isolates the boiling tap only The LCD shows isolation mode is active 5 To d...

Страница 19: ...e Child safety lock see P10 No water flow from mixer tap Faulty non return valve Check and Replace faulty non return valves 3 11 Faulty restrictaflow valve Clean and reset restrictaflow valve item 20...

Страница 20: ...Months Domestic HydroTap Parts Labour Parts Labour Replacement 25 rrp Replacement 33 rrp Replacement 50 rrp HydroBoil Parts Labour Parts Labour Replacement 25 rrp Replacement 33 rrp Replacement 50 rrp...

Отзывы: