Page 2 of 20
HydroTap Installation and Operating Instructions
Contents
Read These Warnings First . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Special tools required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 8
Operating the Mixer Tap . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Mains version connections (diagrams) . . . . . . . . . . . . . . . . . 10 - 11
Vented version connections (diagrams) . . . . . . . . . . . . . . . . . 12 - 13
Operating the HydroTap. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Replacing the Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Setting the Energy Saver Timer . . . . . . . . . . . . . . . . . . . . . . . 15 - 17
Auxiliary Fan Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Boiling Safety Isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Setting Boiling and Chilled dispensing Times. . . . . . . . . . . . . 18
End of Life Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Warranty / Contact Information . . . . . . . . . . . . . . . . . . . . . . . 20
Hydrotap All -In -One series are able to supply Boiling and Chilled water as well as Hot and Cold water, all from the same
tap.
The ‘A’ series have their Boiling / Chilled / Hot and Cold outlets connected to the undersink (open vented) unit.
The ‘AV’ series have their Boiling / Chilled outlets connected to the undersink (open vented) unit and their Hot and Cold
mixer outlets are connected to external (Mains) Hot water and Cold water supplies.
Product Description
NOTE:
All plumbing must comply with AS3500.4.1 &
AS 3500.4.2
All electrical must comply with AS/NZS 3000
All refrigeration must comply with AS/NZS
3350.2.24
The estimated temperature ranges will be:
Boiling water:
68°C - 98°C
Mixed water:
From ambient up to 30°C above ambient
Cold water:
Ambient.
Chilled water:
5°C - 10°C