HydroTap Installation and Operating Instructions  

                              Page 3 of 20

 Read These Warnings First

Safety

This appliance is not intended for use by persons (Including Children) with 
reduced physical, sensory or mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision or instruction concerning 
use of the appliance by a person responsible for their safety.

Children should be supervised to ensure they do not play with the appliance

Refrigerant

The  HydroTap Chilling unit contains 134A refrigerant under pressure. No part of 
the unit should be exposed to a naked flame. Maintenance of the refrigeration 
unit must be carried out by an accredited service provider or qualified 
refrigeration mechanic.

Qualifications

If the power cable is damaged it must be repaired only by a qualified technician. 
To avoid hazards, all installation procedures must be carried out by a suitably 
qualified tradesperson. The power cable and power outlet must be in a safe 
visible position for connection.

Venting

Sometimes steam and / or boiling water may discharge through a vent outlet at 
the mouth of the tap. It is important to ensure the tap body is located so the tap 
outlet safely drains into the sink bowl area. (see details on P10).

NOTE:

 On startup, the controls take the system through a calibration process 

which causes the unit to over-boil for a period of 90 secs. Once this mode is 
completed the system reverts back to normal operation.

Lifting

Take care when lifting the  HydroTap undersink unit. Some units may exceed 
safe lifting limits. If you feel this is beyond your personal capabilities, please 
seek assistance with the lift. The weights of the units are marked on the 
packaging and given in the table under the heading “Installation Requirements”. 
Do not lift the unit by the doors. 

Airflow

The ambient temperatures this unit should operate within are 5ºC -  35ºC. Proper 
air circulation must be provided. The system will operate satisfactorily only if 
the recommended air gaps are provided, these are 65mm min rear clearance 
and 50mm side clearance. An air vent is provided with each unit for high usage 
applications, this must be installed in the top half of the cupboard door as a 
matter of course. An accessory exhaust fan kit is available and should be used 
to ensure adequate ventilation. Make sure that the ventilation grilles of the 
undersink unit are not obstructed. 

I

ncluded in the installation pack are adhesive 

backed silicon buffers. If air vents are not installed in the cupboards housing the 
HydroTap, the buffers must be placed on the inside edge of the cupboard door 
to create a slight gap  ensuring a minimum airflow. Failure to do this may cause 
the HydroTap to overheat and operate inefficiently.

Minimum Pressure warning:

All A and AV models require a minimum cold water supply pressure of 200 kPa 
and a maximum of 700 kPa.                                                                                

Filter Control 

The  HydroTap filter control is preset to 6000 Litres to provide trouble-free flow 
and operation in most installations. Local water quality conditions may require an 
alteration to this capacity. In areas where the water has a high concentration of 
sediment, the preset litre capacity may be shortened to avoid poor flow, taste or 
odour situations. In areas where the water quality is above average, lengthening 
the preset capacity may be desirable, but not essential. If any of these changes 

 Hydrotap undersink assembly.

The appliance must be placed in a 

horizontal position, as shown above.

Note:

Always ensure the tubes are 
shortened so that any excess is 
removed and their route is the 
most direct line between the tap 
assembly and the HydroTap unit.

 Do not allow the tubes to sag or 
droop so water is trapped within 
the hoses. Always maintain a 
constant fall

Positioning of the tap assembly 
must be within the following 
parameters:

The height between the base of 
the Hydrotap unit and the base 
of the Tap assembly cannot be 
greater than 900mm.

The power point must be located within 
reach of its cable. The appliance must be 
positioned so that the plug is accessible.

Содержание HydroTap All-In-One 89944

Страница 1: ...e 1 of 20 Zip HydroTap All In One Filtered Boiling and Chilled water plus Hot and Cold water for kitchens and tea rooms Installation and Operating Instructions This Installation Instruction covers the...

Страница 2: ...on 20 Hydrotap All In One series are able to supply Boiling and Chilled water as well as Hot and Cold water all from the same tap The A series have their Boiling Chilled Hot and Cold outlets connected...

Страница 3: ...ded The system will operate satisfactorily only if the recommended air gaps are provided these are 65mm min rear clearance and 50mm side clearance An air vent is provided with each unit for high usage...

Страница 4: ...ollow the instructions on page 15 16 or contact your Service Provider Frost Protection If this appliance is located where the ambient air temperature could fall below 5 C when the heater is not in use...

Страница 5: ...t tightly against the bench sink top NOTE 1 The tap assembly must not be positioned more than 900mm above the HydroTap unit Failure to do this may result in poor water delivery NOTE 2 Under no circums...

Страница 6: ...y to tighten the hose firmly by hand Excess force may damage the O rings Check these joints for leaks during initial operation Measure and trim the blue silicon tube and connect it to the chilled wate...

Страница 7: ...Orient the USB plug carefully and connect do not force the plug Once connected fix the cable to the wall ensure it is away from any possible water splashes and is off the floor Fasten the tap body to...

Страница 8: ...it at that temperature for a short stabilization period Once stabilized the element will cycle ON bring the water to boiling point and hold it there for a short period The unit now carries out a self...

Страница 9: ...ing the handle up will decrease the flow rate and lowering the handle will increase the flow rate Lift the handle all the way up to turn the tap off When the handle is moved to the left the temperatur...

Страница 10: ...TO TAP 240V GPO NOTE IF THE FLOW RATE IS TOO FAST CUT THE RED SILICONE TUBE 75mm MINIMUM FROM THE BOTTOM OF THE BASE OF THE ALL IN ONE TAP INSERT THE TEFLON RESTRICTOR ABOUT 20mm INTO THE UPPER SEGME...

Страница 11: ...65 220 BENCHTOP CABINET DOOR 4mm BUFFER PAD TO ENSURE VENTILATION GAP BRAIDED HOSE BH1 FROM MAINS SUPPLY BRAIDED HOSE BH2 FROM DOMESTIC HOT WATER SUPPLY SILICONE HOSE FROM BOILING WATER TANK IN HYDRO...

Страница 12: ...ROM STEAM VENT IN HYDROTAP TO TAP SILICONE HOSE FROM CHILLED WATER TANK IN HYDROTAP UNIT TO TAP BH1 B H 2 B H 3 NOTE IF THE FLOW RATE IS TOO FAST CUT THE RED SILICONE TUBE 75mm MINIMUM FROM THE BOTTOM...

Страница 13: ...ALL IN ONE TAP VENTED VERSION MAINS AMBIENT WATER SUPPLY ISOLATION VALVE NOT SUPPLIED 220 65...

Страница 14: ...ing slowly The light will flash slowly when the filter is due for replacement and the LCD will show Filter Change Refer to Replacing the filter section of this document Boiling Water Lever Depressing...

Страница 15: ...ent cartridge and write today s date where shown on the label 8 Avoid touching the filter O rings and filter opening as this may cause bacterial contamination of the cartridge 9 Align cartridge tabs w...

Страница 16: ...o reset the Filter Change display after a filter has reached the end of its life refer to Replace Filter Instructions section of this document Press either Mode or Mode button until Litres Filtered is...

Страница 17: ...vice mode To access the service mode Press both the Adjust and Adjust buttons simultaneously and hold for several seconds until the screen displays the HOT and COLD temperatures Press the Mode button...

Страница 18: ...k 3 three times rapidly the LED s will scroll from left to right 3 three times This operation confirms the activation 4 This isolates the boiling tap only The LCD shows isolation mode is active 5 To d...

Страница 19: ...e Child safety lock see P10 No water flow from mixer tap Faulty non return valve Check and Replace faulty non return valves 3 11 Faulty restrictaflow valve Clean and reset restrictaflow valve item 20...

Страница 20: ...Months Domestic HydroTap Parts Labour Parts Labour Replacement 25 rrp Replacement 33 rrp Replacement 50 rrp HydroBoil Parts Labour Parts Labour Replacement 25 rrp Replacement 33 rrp Replacement 50 rrp...