Zip HydroTap 3-in-1 Скачать руководство пользователя страница 15

Page 15 of 24 

                                   

HydroTap Installation and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1.05

Blue Chilled Water Light
On all the time: 

This indicates that the temperature of the chilled water is within the usable 
temperature range. 

Flashing slowly : 

This indicates that the chilled water is not at the right temperature. Wait up to 
20 minutes. When the chilled water is at the right temperature, the light will 
stop flashing. Note: The Zip HydroTap is designed to dispense chilled water in 
the temperature range 5°C to 15°C.

During heavy usage, the temperature can rise out of this range.
Red Boiling Water Light 
On all the time: 

This indicates that the boiling water is ready. 

Flashing slowly : 

This indicates that the boiling water is below usable 

temperature.

 

Filter Change Light Off: 

This indicates the filter is operating within its normal 

specified life span.

Filter Change Light Flashing slowly : 

The light will flash slowly when the 

filter is due for replacement and the LCD will show “Filter Change”. Refer to  
“Replacing the filter” section of this document.  

Boiling Water Lever  

Depressing the “Red” lever allows dispensing of Boiling water. 
Pulling up the Red lever allows the tap to operate in a “no-touch” mode. Water 
will flow

 

from between 5 and 15 seconds (This is user adjustable). To reset, 

return the handle to the “Off” position and repeat the step. The lever has to be 
manually returned to the “Off” position.

Chilled Water Lever 

Depressing the “Blue” lever allows dispensing of Chilled water. Pulling up the 
Blue lever allows the tap to operate in a “no-touch” mode. Water will flow 
from between 5 and 15 seconds (This is user adjustable). To reset, return the 
handle to the “Off” position and repeat the step. The lever has to be manually 
returned to the “Off” position.

Child Safety Lock (4 in 1)

The child safety lock can be activated to prevent boiling water flowing if the 
hot lever is inadvertently activated.

To activate

: First press the safety lock then depress the Blue Chilled water 

lever for a period of approximately ten seconds. The safety lock indicator light 
will now be illuminated.

To de-activate

: First press the safety lock then depress the Blue Chilled water 

lever for a period of approximately ten seconds. The safety lock indicator light 
will now extinguish.

To operate when the lock is ON

, depress both the Red lever and the safety 

lock simultaneously.

Child Safety Lock (3 in 1 )

To activate the child safety lock , go to the LCD display, using menu

<

 or  <

scroll to the Safety Lock display. To turn ON adjust 

<

 to turn OFF adjust  <

button. After about 10 seconds the screen will default to the selected mode. 
When activated the LED on the safety lock will be illuminated. If de-activated 
the LED will be OFF.

To operate when lock is ON, 

depress both the Red lever and the safety lock 

simultaneously.

Note:

 On the Boiling only models 

the Chilled LED is blank.

Boiling

Chilled

Filter Change

Operating the HydroTap

Press or pull lever

Child safety Lock

Содержание HydroTap 3-in-1

Страница 1: ...ydroTap 4 in 1 and Zip HydroTap 3 in 1 Filtered Boiling and Chilled water plus Hot and Cold water for kitchens and tea rooms Installation and Operating Instructions This Installation Instruction cover...

Страница 2: ...HydroTap Installation and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1 05...

Страница 3: ...the under counter cupboard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all...

Страница 4: ...d BC assemblies which have been factory modified to accept a secondary mixer tap The mixer tap is connected so that it draws water directly from the cold water mains as well as from the boiling water...

Страница 5: ...responsibility to supply if necessary and install all valves as required by local regulations and relevant standards The plumbing installation must be done in accordance with local Water Authority re...

Страница 6: ...unit is intended for indoor use only and should never be installed outdoors or exposed to the elements of nature This unit must not be positioned in an area that may be cleaned by a water jet and mus...

Страница 7: ...ation site Sufficient space in the cupboard to install the undersink unit in accordance with these Installation Instructions A table of dimensions is given above NOTE Add 65mm to the Depth of the unde...

Страница 8: ...nut to the All Thread using the tube spanner supplied in the kit Check the Tap Head position before securing it tightly against the bench sink top NOTE 1 The tap assembly must not be positioned more...

Страница 9: ...he undersink unit SPECIAL NOTE The HydroTap undersink units are heavy take note of the weights listed in the table on page 7 If you think you cannot lift the unit safely get help and avoid possible in...

Страница 10: ...ny excess or allow kinking of the tubes When connecting slide the tube over the pipe at least 25mm There are black plastic clamps provided on the boiling and chilled hoses to choke the flow if require...

Страница 11: ...responds to the direction indicated by the arrow on the filter head and by the instructions listed on the rear panel of the under sink unit Check the lower left hand John Guest fitting is the Inlet fr...

Страница 12: ...and exit model description selection setting 4 The model selection is now complete The Start Filt Flush will be displayed Fig d Start Filt Flush Press Adjust Fig d Scroll Exit BC160 125 Press ADJUST o...

Страница 13: ...nce to return to the service default screen To change the service default screen back to Normal Operation press the adjust buttons together until the screen changes back Warning Caution must be observ...

Страница 14: ...n trap spigot available If a spigot is not available use the snap on spigot and worm drive clamps supplied in the kit Instructions and diagrams are supplied in the kit 8 Ensure the positioning of the...

Страница 15: ...to be manually returned to the Off position Chilled Water Lever Depressing the Blue lever allows dispensing of Chilled water Pulling up the Blue lever allows the tap to operate in a no touch mode Wate...

Страница 16: ...ox 10 seconds it will default to the selected mode The Zip HydroTap notifies when filter replacement is due The default setting is 6000 litres but this can be set in increments of 1000 litres from 100...

Страница 17: ...touching the filter O rings and filter opening as this may cause bacterial contamination of the cartridge 9 Align cartridge tabs with the slots on the under side of the filter head 10 Slide cartridge...

Страница 18: ...once and Monday Off will be displayed Now press Adjust until required time is reached If each individual day is to have an On Off time these steps need to be repeated for each day and for each On Off...

Страница 19: ...enu and selecting de activate when Hot isolation Mode is displayed on the screen 7 The LCD will show Normal Operation Set The Boiling Chilled Water Dispensing Times The ability to change the maximum d...

Страница 20: ...Boiling water to any one sink or may be fitted with a Font kit when a sink is not available The Font must be connected to a suitable drain NOTE The Venturi connection for the 4 in 1 Mixer tap is locat...

Страница 21: ...lves 1 2 Page 22 Faulty restrictaflow valve Clean and reset restrictaflow valve item 3 Page 22 Water supply not connected Check plumbing connection turn water ON No hot water from mixer Hot tank empty...

Страница 22: ...ion and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1 05 Page 22 of 24 Trouble Shooting Continued 1 2 3 Item Description Part No 1 Chec Valve 15mm SP88508 2 Check Valve 8mm SP8850...

Страница 23: ...Page 23 of 24 HydroTap Installation and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1 05 Notes...

Страница 24: ...s incurred by a Zip Service Provider or the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty...

Отзывы: