Filter maintenance
Warning: If the Zip
HydroTap
®
G4 is switched off for
a long period of time (e.g. more
than a weekend), run water
through the AMBIENT water
outlet for at least 5 minutes
before consumption.
•
Caution.
A
small amount of water will drip as the cartridge is
removed.
•
Do not tilt the cartridge as water may spill from it if tilted.
•
Unpack replacement cartridge and remove sanitary cap, write today’s
date where shown on the label.
•
Avoid touching the filter o-rings and filter opening as this may cause
bacterial contamination of the cartridge.
•
Moisten the o-rings with water, align the front cartridge label to the
left (as shown in the “insert filter” diagram below), and push the new
cartridge up into the filter head.
•
Turn the cartridge a quarter turn anticlockwise until the cartridge comes
to complete stop and is locked into position, with the front label facing
forward.
•
Initiate the filter flush programme by scrolling through the menu screen
(see page 13).
•
When completed, wipe up any spills and dispose of spent filter cartridge
and packaging thoughtfully.
•
Close the door to secure the appliance.
•
Adjust the filter settings in Section G (see page 18) litres and days.