Cleaning

General cleaning

Do not use strong, corrosive spray or abrasive cleaners / chemicals. 

Clean the casing, tapware, external filter, piping and all other fittings with a soft cloth 

and mild soap and water. 

Do not spray water over the tap as it may damage the low-voltage electronics.

Caution: Should any of the plastic fittings accidentally come into contact with cleaners 

with a PH level less than 4, hypochlorite, hydrogen peroxide or any other aggressive 

chemical the affected component must be replaced immediately.

Command-Centre

TM

 units must never be located near, or cleaned with water jets. 

Avoid using airborne pesticides near the Command-Centre

TM

.

Website: www.zipwater.com/uk

Email: [email protected]

Facsimile: 01362 692 448

Telephone: 0845 6 005 005

Mobile: 0345 6 005 005

Safety switch is enabled.

 

The HydroTap

®

G4 will not dispense any Boiling water.

See page 3 for safety lock operation.

Safety switch is disabled. 

Boiling water may be dispensed. See page 3 for tap operation details.

Sleep mode is active.

There are 7 sleep mode options which display this icon on the home screen. 

See page 19

 

for details.

Heater is in off mode.

 

When this icon is displayed, no power is being supplied to the heating 

element. See page 19 for Energy Mode options.

Filter use

This icon displays the filter usage remaining from 100% (new filter) to 0% 

(end of life). When it reaches 0% the filter warning light on the tap head will 

flash slowly. The filter life can be adjusted by litres and by days used.  

50%

Boiling temperature

The set temperature of the water in the Boiling tank will be displayed. This 
is optimises at 98°C but may be adjusted between 68°C- 98°C. See page 
17 for hot set point adjustment.

Head Office

 

Zip Water UK

14 Bertie Ward Way

Dereham

Norfolk NR191TE
As Zip policy is one of continuous product improvement, changes to specifications may 

be made without prior notice. Images in this booklet have been modified and may not 

be true representations of the finished goods.

For terms of warranty please see the back page of the installation guide, download the 

latest copy from www.zipwater.com/uk

The terms “Zip” and “HydroTap” are registered trade marks of Zip 

Heaters (Aust) Pty Ltd. 

Zip products described in this publication are manufactured under 

one or more of the following patents: AU675601, AU637412, 

AU635979, GB0422305, GB2065848, US4354049, US5103859, 

US5099825 and SA2006/08043. Other patents are in force and 

patent applications are pending.

Home menu icon 

Home menu icons

Содержание 801621UK

Страница 1: ...801621UK G4 Commercial boiling ambient User Guide Jan 2016 V2 02 Page 1 of 24 Affix model number label here 801621UK ZIP HydroTap G4 User Guide...

Страница 2: ...2 Tap safety Page 3 Tap operation Pages 4 to 7 Safety sensor calibration Page 8 Tap lights Page 8 to 9 LCD screen menu Pages 10 to 22 Filter maintenance Pages 22 to 23 Home menu icons Page 24 Contact...

Страница 3: ...Classic or touch the AMBIENT button Elite keep both fingers in position for a period of approximately ten seconds The safety lock indicator light will illuminate Classic only To deactivate the safety...

Страница 4: ...on Classic Depress the red BOILING lever while simultaneously covering the safety lock button with a second finger These two actions need to occur within 2 seconds for the successful dispensing of bo...

Страница 5: ...ispense ambient water Classic Depressing the blue AMBIENT lever allows the dispensing of AMBIENT water Pulling forward the blue AMBIENT lever allows the tap to operate in a no touch mode Water will fl...

Страница 6: ...orward direction and when released will return to the OFF position When rotated in the reverse direction the tap operates in a POT FILL mode Water will flow from between 5 and 15 seconds This is user...

Страница 7: ...The final temperature will be dependant on the temperature of the incoming cold water Increase flow Decrease flow Cold Hot Classic mixer Arc mixer Cube mixer Arc Cube mixer taps Moving the lever away...

Страница 8: ...the installation All direct sunlight must be shaded from the HydroTap G4 during the calibration This can be achieved by closing any nearby curtains blinds etc Safety sensor calibration Tap lights Blue...

Страница 9: ...ent Filter light Classic and Elite Filter light off This indicates the filter is operating within its normal specified lifespan Filter light flashing slowly The light will flash slowly when the filter...

Страница 10: ...Mode System is in sleep mode Boiling water or hot water is not available Refer to section G Energy modes Change Filter External Internal filter needs to be replaced Refer to section C Installation Sys...

Страница 11: ...Filter reset Boiling calibration Booster Lux sensor calibration Start Stop Internal External Calibration options Enable Disable C Service Password protected D Security Enable password Set password Cha...

Страница 12: ...screen Press System Faults to check the fault information Press button for the previous menu or press HOME button to return to the home screen Press Filter Log to check the filter resets Press button...

Страница 13: ...tridge is a flush line approx 600mm long and the flush line stop cock Place the free end of the flush line into the bucket or container not supplied Press MENU button for main menu Press the Install b...

Страница 14: ...he MENU button for main menu Press the Install button Press the Boost button In the next screen press YES to enable the booster dispense boiling water for 30 seconds and check the insulated outlet hos...

Страница 15: ...button A password is required to enter service menu D Service LCD Screen operation Section D 5 Lux sensor calibration Press the MENU button for main menu Press the Install button Press the Lux Sensor...

Страница 16: ...eration Section E To change a password Press the MENU button for main menu Press the Security button Press Change Password Enter your old 4 digit password Then enter your new 4 digit password press En...

Страница 17: ...utton Choose 12 HOUR mode or 24 HOUR mode by pressing the square button The selected mode will be displayed in dark grey colour with a tick box on the right Press NEXT button to set time Set Date Time...

Страница 18: ...aximum of 10000 litres Factory set at 6000 litres To edit the filter usage This function is to reset the filter change display after a filter has reached the end of its life see page 22 Filter mainten...

Страница 19: ...ttings button Enter your 4 digit password and press Enter Press the Energy Modes button Press the Sleep Modes button then in the next screen use the up and down arrow to select sleep mode from the 7 o...

Страница 20: ...at a specific time To activate On Off mode Press the MENU button for main menu Press the Settings button Enter your 4 digit password and press Enter Press the Energy Modes button then On Off Modes Men...

Страница 21: ...afety lock feature Then press button to enable hot isolation To de activate press button to disable hot isolation Then press button to enable disable the safety lock To operate the tap when in hot iso...

Страница 22: ...ep a towel handy to dry up any drips To change the filter Open the door of the Command CentreTM Relieve system pressure via the filter flush stop cock a quick open and close will do Use the bucket to...

Страница 23: ...ching the filter o rings and filter opening as this may cause bacterial contamination of the cartridge Moisten the o rings with water align the front cartridge label to the left as shown in the insert...

Страница 24: ...reen See page 19 for details Heater is in off mode When this icon is displayed no power is being supplied to the heating element See page 19 for Energy Mode options Filter use This icon displays the f...