Page 18 of 24
801621UK G4 Commercial boiling (ambient), User Guide - Jan 2016 - V2.02
3.
LCD Screen operation - Section G
Filter
Zip HydroTap
®
G4 allows the user to adjust filter life and edit filter usage.
To edit the filter life
Press the [MENU] button for main
menu.
•
Press the [Settings] button.
•
Enter your 4-digit password and
press [Enter].
•
Press the [Filter] button.
•
Press the [Int Filter Life] / [Ext
Filter Life] button.
•
To change filter life, first select
(Litres) or (Months) then press the
up or down arrows to edit filter life.
Note
Filter life increases in 500 litres
increments to a maximum of 10000
litres. Factory set at 6000 litres.
To edit the filter usage
This function is to reset the filter change
display after a filter has reached the
end of its life (see page 22 Filter
maintenance).
•
Press the [MENU] button for main
menu.
•
Press the [Settings] button.
•
Enter your 4-digit password and
press [Enter].
•
Press the [Filter] button.
•
Press the [Edit Int Filter] / [Edit
Ext Filter] button.
•
To change filter usage, first select
(Litres) or (Days), then use the up
and down arrows to edit the filter
usage.
Note
The filter life may be set as a
function of litres used, or in months
from the filter change. When the first of
these functions is reached (i.e. litres or
months expired), the filter warning light
will be illuminated on the tap.
Either of these functions may be
disabled.