22
10.2.9 Mounting LWR50F-14-04-A and LWR50F-14-05-A
Activation is done via SCM or a commercially available IO-Link master with Port Class B.
pin Color
Function
Explanation
4
2
1
8
12
9
6
3
7
5
11
10
M12, 12-pin Connector straight
5
Pink
+ 24 V DC sensor
IO-Link communication supply
6
Yellow
+ 24 V DC actuator
Actuator supply voltage
7
Black
C/Q
IO-Link communication
8
Gray
GND sensor and
actuator
0 V sensor and actuator supply voltage
10.2.10 Mounting LWR50F-15-01-A
pin Color
Function
Explanation
4
2
1
8
12
9
6
3
7
5
11
10
M12, 12-pin Connector straight
1
Brown
+ 24 V DC
+ 24 V DC supply voltage
2
Blue
Input 2
Outward move command
3
White
GND
0 V supply voltage
4
Green
Input 1
Inward move command
5
Pink
Analog output
0 to 10 V DC output
6
Yellow
Output 3
Connect signal: 24 V if loose part is coupled.
7
Black
Output 1
Outside signal
8
Gray
Output 2
Inside signal inside
The inputs of the product are configured for PNP outputs of the control system.
10.2.11 Mounting LWR50F-15-04-A and LWR50F-15-05-A
Activation is done via SCM or a commercially available IO-Link master with Port Class B.
pin Color
Function
Explanation
4
2
1
8
12
9
6
3
7
5
11
10
M12, 12-pin Connector straight
1
Brown
+ 24 V DC sensor
IO-Link communication supply
2
Blue
+ 24 V DC actuator
Actuator supply voltage
3
White
GND sensor
0 V sensor supply voltage
4
Green
C/Q
IO-Link communication
8
Gray
GND actuator
0 V actuator supply voltage