12
6.3.1 Wiring diagram sensor system
Sensor plug connection M8 3-pin:
4
1
3
Graphical symbol for sensor in storage position
2 sensors in inspection position connected in series
+
-
1
3
4
Power Supply
Safety Input
+
-
1
3
4
Power Supply
Safety Input
+
-
1
3
4
Safety Input
6.3.2 Adjust the sensors in the inspection
position
bq
br
►
Bring the markings on the locking elements
of the loose part to the position of the front
markings of the storage station.
►
Turn in the sensors until they emit a signal.
►
Fasten the sensors at this position.
►
Coat the sensors with sealing lacquer.
6.3.3 Adjust the sensors in the storage
position
►
Position a loose part in the storage station.
►
Turn in the sensors until they emit a signal.
►
Coat the sensors with sealing lacquer.
bq
Sensor in storage position (loose part
present)
br
Sensor in inspection position (test
channel, locking extended)
INSTALLATION AND OPERATION INSTRUCTIONS:
LWR50F
DDOC01074 / b
EN / 2021-09-15
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com
Содержание LWR50F Series