10.3.1 Checking the clamping force
►
Check the clamping force of the clamping system before commissioning.
Ö
Use an appropriate clamping force measurement device that corresponds to the holder.
Ö
The clamping force must be >8 kN.
Ö
If the clamping force is below 8 kN, the clamping set must be cleaned.
Ö
If the clamping force continues to be below 8 kN after cleaning, the clamping set must be replaced.
Ö
If the clamping force continues to be below 8 kN after being replaced, the tool clamp must be replaced by the
manufacturer.
Ö
Therefore, the complete product on the machine or system must be replaced.
10.4 Checking the tool interface (analog sensor and switching states)
DANGER:
Risk of fatal injury as a result of prohibited tool interface clamping states!
Ö
The product may only be operated if the state "Clamped with tool" is met.
Ö
Otherwise, a loss/ejection of the tool during operation/rotation cannot be ruled out!
Ö
Injury to personnel or material damage may result.
The analog sensor installed in the product monitors the clamping states of the tool interface. The analog sensor outputs
corresponding values as a voltage value [V] based on the clamping state.
The product converts the signal from the analog sensor into digital switching states.
Possible clamping states:
•
Clamped without tool (tool clamp completely retracted)
•
Clamped with tool (tool clamp actuated with tool)
•
Tool unclamped (tool clamp is completely extended)
Ö
Make sure that it is not possible to operate the product outside of the required switching states.
Ö
Use an appropriate switching logic to ensure that operation/rotation of the product is not possible.
Ö
See the "Technical datasheet" circuit diagram.