39
Error code
Error
Possible cause
Measure
0x0000
Device is ready for operation.
-
-
0x0002
Position measuring system not
referenced.
•
Product does not have any
reference position.
►
Please contact Zimmer
Customer Service.
0x0003
Device is booted up.
•
The device is in the start
sequence.
►
Wait until the start sequence
is complete.
0x0100
Actuator power supply is not
present or is too low
•
Actuator power supply is not
connected
•
Actuator power supply is not
sufficient
•
Cable break
►
Check the actuator power
supply.
0x0101
Temperature above maximum
permitted temperature.
• Ambient temperature is too
high.
•
Overload of the products.
►
Provide sufficient ventilation/
cooling/connection.
►
Check that the product
moves freely.
0x0102
Temperature is below minimum
permitted temperature.
• Ambient temperature is too
low.
►
Provide an adequate
operating temperature.
0x0103
Temperature of the power level
is too high
• Surrounding temperature is
too high
•
Overload of the product
•
Internal defect
►
Ensure improved cooling of
the product.
►
Check that the product
moves freely.
►
Increase the break time
between the gripping
movements.
0x010B
Workpiece lost
•
Gripping force is not
sufficient
•
Workpiece was not gripped
correctly
• Gripper finger geometry
does not match the gripped
workpiece
•
Workpiece is too heavy
►
Check the required gripping
force.
►
Check the gripper finger
geometry.
►
Reset the error by sending
another move command
back.
0x0300
ControlWord is not plausible.
•
Multiple bits were set in the
ControlWord.
►
In the ControlWord, check
that only one bit is set.
0x0301
Position implausible
• Transmitted TeachPosition is
not plausible.
►
Check the transmitted
process data.
• Permissible range,
depending on installation
size: Jaw stroke x 200
Example: GEP2016 with jaw
stroke of approx. 16.1 mm
results in a value of 3220.
0x0302
GripForce is not plausible.
• Transmitted GripForce is not
plausible.
►
Check the transmitted
process data.
0x0304
PositionTolerance is not
plausible.
• Transmitted PositionTol
-
erance is not plausible.
►
Check the transmitted
process data.
0x0305
Erroneous reference position
•
Product does not have any
reference position.
►
Please contact Zimmer
Customer Service.
0x0306
DeviceMode is not plausible.
• Transmitted DeviceMode is
not plausible.
►
Check the transmitted
process data.
14 Error diagnosis