43
Index
Name
Data
format
Access rights
Values
Description
0x0114
(276)
Subindex
1 to 4
WorkPosition/
BasePosition
tolerance window
UINT16
Read/write
0 ... 65535
►
Setting the BasePosition
and WorkPosition tolerance
window
• Subindex 0: Read/write
• Subindex 1: from BasePo
-
sition to the outside
• Subindex 2: from BasePo
-
sition to the inside
• Subindex 3: from WorkPo
-
sition to the inside
• Subindex 4: from WorkPo
-
sition to the outside
►
Resetting all changes to
factory settings using an
IO-Link factory reset
0x022f
(559)
Holding current
UINT16
Read/write
0 to 1100
Amperage [%] for current
after-supply scaled to the
maximum permitted current.
0x0230
(560)
Holding time
UINT16
Read/write
0 to 1000
Time duration [ms] for current
after-supply
0x0232
(562)
Emergency Mode
UINT16
Read/write
0 to 1
►
Deactivation of message
0x0400 by ISDU:
• Index = 562 (decimal)
• Subindex = 0
• Value = 0
►
Activation of message
0x0400 by ISDU:
• Index = 562 (decimal)
• Subindex = 0
• Value = 1