11.2 Troubleshooting display for GEP5000IO/GED5000IO
Error code
Error
Possible cause
Measure
1
5
Gripper is ready for operation
No error
-
-
1
5
Motor has slight overcurrent in multi-
ple consecutively following cycles
•
Gripper is difficult to move
• Travel path of the gripper is
impeded
• Object being gripped or gripper
fingers are elastic
• Check the gripper's freedom
of movement
• Check the object being
gripped and the gripper
fingers
1
5
Motor has strong excess current
• Gripper is jammed
• Internal error
• Restore the gripper's freedom
of movement
►
Zimmer Customer Service
1
5
Motor has excess current in idle
mode
• Internal error
►
Zimmer Customer Service
1
5
Temperature of the motor output
stage above the limit value
• Surrounding temperature too
high
• Gripper is overloaded
•
Provide for sufficient
ventilation/cooling
• Check the object being
gripped and/or the gripper
fingers
1
5
Gripper is in reference run mode
• Internal error
►
Zimmer Customer Service
1
5
Gripper has no reference on the jaw
position
• Gripper has lost its reference
position
►
Zimmer Customer Service
1
5
Motor is in setting run mode at the
end position
• Setting run was started
• CAUTION: do not evaluate the
positions during the setting run!
• Wait for completion of the
setting process
1
5
Gripper does not reach the end
position
(Work, teach and base position)
• Gripper does not reach the work,
teach and base position
• Check the object being
gripped and/or the gripper
fingers