![Zimmer GED5000IL Series Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/zimmer/ged5000il-series/ged5000il-series_installation-and-operating-instructions-manual_933962021.webp)
Zimmer GmbH
•
Am Glockenloch 2
•
77866 Rheinau, Germany
•
+49 7844 9138 0
•
+49 7844 9138 80
•
www.zimmer-group.com
21
INSTALLATION AND OPERATING IN-
STRUCTIONS:
GEP5000/GED5000 electric gripper series
EN / 05/01/2021
DDOC00211/i
8 Commissioning
8.1 Commissioning for GEP5000IO-00/GED5000IO-00
8.1.1
Switch sequence
A movement in the desired direction occurs when the corresponding signal is at a high level. After a high level is detected,
the gripper movement occurs until the gripping process ends.
It is important to ensure that, after a gripper movement has taken place, the corresponding signal is reset again before a
signal in the opposite direction is given.
Between withdrawing the signal and the next command, a pause time of 10 ms must be adhered to.
INFORMATION
The movement profile only applies to the digital gripper of the GEP5000IO-00/GED5000IO-00 series.
0 V
24 V
Imax
≤
5 A
Eingang 1 DIR
Stromaufnahme
Greiferpostion
►◄
◄►