INSTALLATION AND OPERATING IN-
STRUCTIONS:
GEP5000/GED5000 electric gripper series
EN / 05/01/2021
DDOC00211/i
11 Error diagnosis
11.1 Troubleshooting display for GEP5000IL/GED5000IL
Error code Error
Possible cause
Measure
0x0
No error
-
-
0x100
Actuator power supply is not
present or is too low.
• Actuator power supply is not
connected.
• Cable break
• Actuator power supply is not
sufficient.
►
Check the actuator power
supply.
0x101
Temperature above maximum
permitted temperature.
• Ambient temperature is too
high.
• Overload of the products.
►
Provide sufficient ventilation/
cooling/connection.
0x102
Temperature below minimum
permitted temperature.
• Ambient temperature is too low.
►
Ensure a sufficient operating
temperature.
0x300
The configured "ControlWord" is
implausible.
• Multiple bits are set in
"ControlWord."
►
Only one bit is permitted to be
active in "ControlWord."
0x301
The configured "TeachPosition" is
outside the permitted range.
• Incorrect value on the
"TeachPosition."
►
Check the "TeachPosition"
parameter.
►
Permissible range, depending
on design size.
►
Maximum position value
corresponds to the jaw stroke
x 200.
0x302
The configured gripping force is
outside the permitted range.
• Incorrect value in the
"GripForce" parameter.
►
Check the "GripForce"
parameter.
►
Permitted range: 0 <
"GripForce" ≤ 4
0x304
The configured tolerance value is
outside the permitted range.
• Incorrect value in the "Position-
Tolerance" parameter.
►
Check the "PositionTolerance"
parameter.
►
Permitted range: 0 < "Position-
Tolerance" ≤ 255
0x305
The device has an incorrect
reference position.
• Product does not have any
reference position.
►
Zimmer Customer Service
0x306
The configured "DeviceMode" is
implausible.
• Incorrect value in the
"DeviceMode" parameter.
►
Adjust the "DeviceMode"
►
Universal = 100
►
Grip workpiece outside = 60
►
Grip workpiece inside = 70