8.2 Commissioning for GEP5000IL-00/GED5000IL-00
8.2.1 Process data
There is an option to control the product only with the process data that is transmitted in each cycle.
Outputs: Process data from the IO-Link master to the product!
Name
Data type
ControlWord
UINT16
DeviceMode
UINT8
Workpiece No.
UINT8
TeachPosition
UINT16
GripForce
UINT8
PositionTolerance
UINT8
Steuerung
Produkt
Eingang
Ausgang
Name
Data type
StatusWord
UINT16
Diagnosis
UINT16
ActualPosition
UINT16
When the hardware configuration is complete and the IO-Link connection to the product is established, some data must be
visible in the process input data.
Ö
Some control systems demand a byte swap to bring this process data into a logical sequence.
►
To determine whether a byte swap is necessary, you can view bit 6 (GripperPLCActive) in the "StatusWord."
►
For this purpose, it is necessary to determine whether bit 6 is active in the first or second status byte.
Ö
If bit 6 is active in the first byte, the bytes already have the correct sequence and commissioning can be continued.
Ö
If bit 6 is active in the second byte, a byte swap still has to be applied here.
Ö
For further information, refer to the "StatusWord" section.