Installation and operating instructions
55
10 Technical data
10.1 DC input data
Type
TLC 10K
TLC 15K
Rated DC input power (Pdc,r)
10400 W
15600 W
Max. recommended DC input power
at STC
(1)
11500 W
17250 W
Max. DC input voltage
1000 V
(2) (3)
Rated DC input voltage
640 V
MPP voltage range
270 … 950 V
Full load MPP voltage range
320 … 800 V
340 … 800 V
Start-up DC input voltage
300 V
Min feed-in DC voltage
270 V
Max. DC input current (input A/B)
22 A/ 11A
22 A/ 22 A
Isc PV, absolute Max. (input A/B)
32.4 A/ 16.2 A
32.4 A/ 32.4 A
Number of MPP trackers
2
Strings per MPP tracker (input A/B)
2 / 2
Turn on power
25 W
DC-switch
Optional
Содержание Eversol-TLC 10K
Страница 1: ......