The Table 5.
PROGRAMMING-2
is an example of the sequence of prompts and keystrokes
for programming system parameters.
Table 5. PROGRAMMING-2 System Programming Example
Prompt
Keystroke Explanation
SEtUP
C and CLEAR
together
Displaying the SEtUP prompt indicates that no formats have
been programmed. Hold the C and CLEAR keys down together.
ConFiG
Release keys
Displaying ConFiG confirms entering the program mode.
diGt=0
PAGE
Pressing the PAGE key will toggle between the leading digit
prompt and the system prompt.
SYStEM
ENTER
Pressing the ENTER key will select the system function
programming mode.
tLH=0
10, ENTER
Talk time in seconds. If voice-capable pagers are used, this will
set the amount of time allowed for voice messages after the
page. Pressing ENTER will accept the value displayed and
proceed to the next prompt.
binP=0
ENTER
Binary polarity. Pressing ENTER will accept the value displayed
and proceed to the next prompt. Unless you know you need to
invert this parameter, leave it at default.
diGP=0
ENTER
Digital Mode polarity. Pressing ENTER will accept the value
displayed and proceed to the next prompt. Unless you know
you need to invert this parameter, leave it at default.
APAG=0
ENTER
Autopage. Pressing ENTER will accept the value displayed and
proceed to the next prompt. Unless you know you need to invert
this parameter, leave it at default.
SCrL=0
ENTER
Autoscroll. Pressing ENTER will accept the value displayed and
proceed to the next prompt. Unless you know you need to invert
this parameter, leave it at default.
cont=0
ENTER
Continuous-test mode. Pressing ENTER will accept the value
displayed and proceed to the next prompt. Testing is the only
time you would change this.
Sid= 0
0 or 1, ENTER
Enables/Disables use of Station Morse Code ID. 0 = Disabled, 1
= Enabled. If enabled, it will be followed by an opportunity to
enter the ID characters.
....
Momentary display indicates all parameters are programmed.
diGt=0
CLEAR
Pressing the CLEAR key exits the program mode. Pressing
PAGE displays the SYStEM prompt again. Entering a digit 0 - D
selects a leading digit for paging format programming.
SAVE Y
Pressing CLEAR
will toggle Yes/No
If you press the CLEAR key at the diGt=0 prompt, this prompt
asks if the unit should save the programmed values from this
session into non-volatile memory. Press ENTER to save data
and exit the program mode.
Содержание 15P
Страница 2: ......
Страница 10: ......
Страница 11: ......
Страница 14: ......
Страница 16: ......
Страница 24: ......
Страница 36: ......
Страница 38: ......
Страница 48: ......
Страница 84: ......
Страница 86: ......
Страница 93: ......
Страница 94: ......
Страница 95: ......
Страница 98: ......
Страница 100: ......