Section 5. Programming
5-3
PROGRAMMING SYSTEM PARAMETERS
A description of the prompts encountered when programming system parameters is presented
in Table 5-1 for easy reference. The mix of upper and lower case characters in the prompts
simulate what is actually viewed on the LED display. To the right of the prompt is a
description of what the prompt is asking for and what responses are valid. The prompts are
presented in the order in which they are encountered while programming the encoder. Should
an improper or out of range value be entered while programming the encoder, the encoder
will not proceed to the next prompt after pressing the ENTER key. Instead it will redisplay
the same prompt and await an allowable value. Out of range entries to prompts for single digit
entries will not be displayed.
Table 5-1 System Programming Parameters
Prompt
Explanation
SYStEM
Pressing ENTER at this prompt starts the programming of system parameters.
tLH= 0
Talk Time - Should Talk be enabled in a paging format, this parameter sets the Talk-
time period. The range is between 00 and 60 in seconds. Keypad entries are shifted
from right to left in the display. If an error is made during entry, continue to press keys
until the correct two digits are displayed. The two digits showing when ENTER is
pressed are the accepted value.
binP=0
Binary Polarity - This parameter selects whether a Logic “0” will appear as a High or
Low level on the Digital output. An acceptable value is 0 or 1.
diGP=0
Digital Mode Polarity - A “0” indicates that TB1 pin 8 will be low for digital mode output,
and a “1” indicates a high output for a digital page.
APAG=0
Autopage - A “1” enables the Autopage feature, sending the page automatically
following entry of the final digit of a page number. Keypad stack may not be used when
Autopage is enabled. A “0” indicates the feature is disabled.
SCrL=0
Autoscroll - “0” = disabled, “1” = enabled The display scrolls through the entire capcode
(including the leading digit) to before sending out a page.
cont=0
Continuous-test Mode - “0” = disabled, “1” = enabled The encoder continuously repeats
the last page entered at one second intervals (until the CLEAR key is pressed). NOTE:
This parameter is not saved in nonvolatile memory and will revert to disabled if the
power is cycled.
Sid= 0
Station ID - This parameter enables or disables the Morse code Station ID feature.
Содержание 15P
Страница 2: ......
Страница 10: ......
Страница 11: ......
Страница 14: ......
Страница 16: ......
Страница 24: ......
Страница 36: ......
Страница 38: ......
Страница 48: ......
Страница 84: ......
Страница 86: ......
Страница 93: ......
Страница 94: ......
Страница 95: ......
Страница 98: ......
Страница 100: ......