AEROLYTE 6060A and 7070A G2 PRESSURE CABINETS
Page 8
© 2016 CLEMCO INDUSTRIES CORP.
www.clemcoindustries.com
Manual No. 27789 Rev. A, 10/16
2.13.3
Loosen the lock nuts and position the damper.
When correctly positioned, tighten the lock nuts to
maintain the setting. Refer to Section 5.6 for adjustment
procedure.
2.14 Final
Assembly
2.14.1
Insert a section of 3/8 tubing into the automatic
drain at the bottom of the compressed-air filter and place
the other end into a pail. When the filter automatically
drains, the water will drain into the pail.
2.14.2
Position the foot pedal on the floor at the front of
the cabinet.
2.14.3
A package of five window cover lenses is
supplied with the cabinet. Install a cover lens per
Section 7.2. When the cover lens becomes pitted or
frosted, replace it.
3.0
FIELD INSTALLED ACCESSORIES
3.1
Curtain Installation, Figure 7
3.1.1
Match the curtains to the corresponding wall and
door as shown in Figure 7. Hook the curtains to the J-
Hooks welded along the top of the front, back, and side
walls. Cut openings for the hoses on the lower left rear wall.
Figure 7
3.1.2
Using protectors against the curtains and outer
doors, clamp the door curtains in place. The upper
edges of the door curtains should be even with the outer
edges of the sound proofing panel. Insert a #10 self-
drilling screw with an 11/16
OD flat washer through the
grommet holes. Use a screw gun with a 5/16" socket to
attach the door curtains.
3.1.3
For front walls, place the batten strip over the
curtain, and clamp it in position on the front slope above
the break as shown in Figure 7. Match drill .187" (3/16")
diameter holes through the rubber and cabinet front at
each batten hole. To install the batten insert #10-24 x 1
round head machine screws through the cabinet front,
curtain and batten. Install lock washers and nuts from
inside the cabinet and tighten securely.
3.2 Manometer
The optional manometer kit is listed in Section 9.1.
3.2.1
Consistent static pressure is necessary for
precise media separation, as the reclaimer's efficiency is
achieved by a centrifugal balance of air flow, particle
weight, and size. The manometer measures static
pressure. Reclaimer static pressure is set by adjusting
the outlet damper; refer to Section 5.3 to adjust static
pressure. Refer to Section 5.7 for manometer
instructions.
3.3 Armrest
3.3.1
Assemble the armrest and mounting brackets as
shown in Figure 8.
3.3.2
Position the assembly so the armrest is about
even with the bottom of the arm-port opening. Mark one
hole location on the front of the cabinet at each
mounting bracket.
Figure
8
3.3.3
Drill a 3/8" hole at both locations and mount the
armrest using 5/16 cap screw, washers and nuts. Install
the bolts from inside the cabinet to protect the threads
from abrasion, should the armrest need to be removed
at a later date.
J-Hook
No. 10 Self- drill Screw
Washer
Nut
Lock Washer
Batten Strip
Machine Screw
5/16 x 1" x Cap Screw,
Flat Washer, Lock
Washer and Nut
Armrest
3/8 x 1" Cap Screw
and Lock Washer